VMware Cloud Community
ncolyer
Enthusiast
Enthusiast

HP Flex 10 - Received Dropped Packets

VMware Community,

We are having a strange issue, which so far VMware/HP support has not been able to solve.

We have an environment where we are using 2 x 10GBps and 2 x 9Gbps adapters on a single DVS.

The DVS supports ESxi Management, vMotion, and Data traffic for the VMs.

We have Resource allocation turned on as well.

The blades are G7s.

Our problem is we are constantly seeing dropped received packets in this cluster. After a lot of research we thought it may be firmware/driver related and went down a whole path of updating our chassis, hosts, drivers, etc to the latest supported config by HP.

Still we are getting dropped received packets. We can recreate it quite easily, by initiating a vMotion.

We've tried running on just the 2 x 10gig and just the 2 x 9gig adapters but this made no difference.

Anyone got any suggestions?

Nick

Tags (4)
43 Replies
Rubeck
Virtuoso
Virtuoso

Have you checked the flow control settings on the physical switch ports?

/Rubeck

ncolyer
Enthusiast
Enthusiast

I've just asked our network engineer to check.

What are we looking for it to be set at? or not be set at?

What's the theory here?

Thanks

Reply
0 Kudos
ncolyer
Enthusiast
Enthusiast

This is how they are configured:

  MTU 1500 bytes, BW 10000000 Kbit, DLY 10 usec,

     reliability 255/255, txload 1/255, rxload 1/255

  Encapsulation ARPA

  Port mode is trunk

  full-duplex, 10 Gb/s, media type is 10g

  Beacon is turned off

  Auto-Negotiation is turned off

  Input flow-control is off, output flow-control is off

Reply
0 Kudos
MKguy
Virtuoso
Virtuoso

>Still we are getting dropped received packets. We can recreate it quite easily, by initiating a vMotion.

Please be more specific on this point. Where exactly do you see those dropped packets (check (r)esxtop)? On the physical uplink of the destination receive-side (%DRPRX) or on the physical uplink/vMotion vmkernel port group of the source host (%DRPTX) or somewhere else? About what magnitude of dropped packets are we talking here, is this just an observation or is it actively causing issues? vMotion can be quite bursty, heavily utilizing a link so it's not odd if you see "a few" dropped packets.

Does the issue occur between hosts within the same chassis, thus never leaving the VC modules and ruling out physical switches?

Do you have an idential MTU set on all systems, vSwitches, vmkernel ports? Jumbo frames on one end could cause the drops apart from general issues such as bad frame CRC sum.

I doubt it's flow-control related, as ESXi will by default only enable flow control for a NIC if the physical switch (or VC module) agrees via auto-negotiation too.

You can check the actual flow control settings on the ESXi side via ethtool –show-pause vmnicX. Enabling flow control on the physical switch ports shouldn't hurt though.

-- http://alpacapowered.wordpress.com
Reply
0 Kudos
bszweda83
Contributor
Contributor

Hi Mkguy, I work with ncolyer so I've decided to respond We noticed when looking at the performance monitor counters that the received dropped packets increment up. I've also been able to capture the received dropped packets by running esxtop in batch mode and then using esxplot. If I were to just look at a default active session of esxtop for %DRPRX I don't see anything that would indicate dropped packets. Example of dropped packets ( Virtual machine with 4 GB of RAM) Counter before vmotion # 312714 Counter after vmotion # 325272 This occurs within the chassis or from chassis to chassis. We have idential MTU set on all systems, vswitches, and vkernel ports. Here is the flow control setting Pause parameters for vmnic21: Autonegotiate:  off RX:            on TX:            on Thanks, Brad

Reply
0 Kudos
ncolyer
Enthusiast
Enthusiast

Anyone got any more tips on this or how to better find out why it is happening?

Reply
0 Kudos
svenherren
Enthusiast
Enthusiast

Hello

we experience exactely the same issue. Got a lot of RX packet drops in our ESXi environment as soon as there is some net traffic on any vmnic. The way with vMotion works also to reproduce the issue. We also have a case open with HP. The forwarded to Emulex. We are still waiting for an answer.

We experience the problem on all AMD Based G7 Blades with a NC551i (Emulex) Nic installed. BL685c G7 and BL465c G7. It does not matter if used in a Flex10 environment or with Passthrough module. All constellations drop packets. G6 or Intel machines also in same enclosures do not drop RX packets at all.

We use:

OS: ESXi 5.0 Build  821926

System: BL685c G7 BIOS A20 08/15/2012

Driver: be2net 4.1.334.0

FW Nic: 4.1.450.16

Did you get any further with this issue?


Regards

Sven

Reply
0 Kudos
ncolyer
Enthusiast
Enthusiast

No we haven't had any further traction on this yet.

We have our case open with HP and they've given us a few things to try to try and isolate it further. We hope to do this in the next few weeks.

Any progress on your side? Our case number with HP is CASE:4685467385, if you wan to reference it in any of your support calls with them as well.

I really think HP should be recreating this issue internally as it doesn't seem to hard to demonstrate. We use vMotions to prove the dropped packets go up on the vMotion NICs during every vMotion.

Reply
0 Kudos
ncolyer
Enthusiast
Enthusiast

Sven,

Any chance you are able to provide me your HP Case number so i can pass it on to our HP Support engineer.  I just mentioned your issue to our HP support engineer, and he can't look at it without it. I'm hoping that HP can find the answer quicker if they have multiple cases.

Nick

Reply
0 Kudos
swehoster
Contributor
Contributor

Hi!

Did you solve this problem?

Reply
0 Kudos
ncolyer
Enthusiast
Enthusiast

Not yet...and no further information from HP yet either.

Anyone else found any answers?

Reply
0 Kudos
kaarol
Contributor
Contributor

Hi,

@Raz1. I have the newest drivers and a firmware for emulex cards and problem still exists. I have two other blade with Broadcom 10Gb driver and I've never seen dropped packages.

Reply
0 Kudos
ncolyer
Enthusiast
Enthusiast

Same for us. Updated Firmware/Drivers and the issue still persists.

We have other G6 blades that do not experience the issue.

Reply
0 Kudos
svenherren
Enthusiast
Enthusiast

Hello everybody

HP and Emulex made some research.

We got a new firmware and beta driver for the be2net CNA adapters today and did some basic testing.

FW:      4.1.450.1705

Driver:    be2net 4.2.327.0 (beta)

The problem IMHO is partly solved. The RX packet drops drastically decreased, but didn't disappear completely. During vMotion peaks we still got some RX packet drops.

According to HP the RX packet drops were not real drops but a miss indication from the driver. But cross checking with a network analyzer we still discovered any retransmits. So i guess there were of course some dropped RX packets 😉

The new firmware and driver should be released soon to public.

Reply
0 Kudos
MKguy
Virtuoso
Virtuoso

Internesting, but be2net driver version "4.2.327.0" was already released back in September:

https://my.vmware.com/group/vmware/details?downloadGroup=DT-ESXI50-Emulex-be2net-423270&productId=28...

>be2net-4.2.327.0-837998.zip

Are you sure that's the correct version numbering?

-- http://alpacapowered.wordpress.com
Reply
0 Kudos
svenherren
Enthusiast
Enthusiast

we received those and are explicitly marked beta (although it is the same version as from vmware):

esx-5.0.0-GA-be2net-4.2.327.0.zip

net-be2net-4-2-327.0-10OEM.500.0.0.472560.x86_64.vib

Reply
0 Kudos
MKguy
Virtuoso
Virtuoso

The VIB contained in the offline bundle I linked has the exact same version name/build number:

net-be2net-4.2.327.0-1OEM.500.0.0.472560.x86_64.vib

I suspect it's a completely identical driver. Can you post the md5/sha1 hash of your VIB file for comparision?

D:\>md5sum.exe net-be2net-4.2.327.0-1OEM.500.0.0.472560.x86_64.vib
209588c8340a7ee958549b8cd957e5e3 *net-be2net-4.2.327.0-1OEM.500.0.0.472560.x86_64.vib

D:\>sha1sum.exe net-be2net-4.2.327.0-1OEM.500.0.0.472560.x86_64.vib
af34ab0580028fa1e4ea7215dd57ca90f0d9220a  net-be2net-4.2.327.0-1OEM.500.0.0.472560.x86_64.vib

-- http://alpacapowered.wordpress.com
Reply
0 Kudos
svenherren
Enthusiast
Enthusiast

Here the output of following commands:

/vmfs/volumes/50d31899-d855d0d8-2533-10604bac98ea/Software # md5sum net-be2net-4.2.327.0-1OEM.500.0.0.472560.x86_64.vib

80faf87fc899b7bdfd2605219f9cbbda  net-be2net-4.2.327.0-1OEM.500.0.0.472560.x86_64.vib

/vmfs/volumes/50d31899-d855d0d8-2533-10604bac98ea/Software # sha1sum net-be2net-4.2.327.0-1OEM.500.0.0.472560.x86_64.vib

ac3190759f7770341423970c7087e69f038e4997  net-be2net-4.2.327.0-1OEM.500.0.0.472560.x86_64.vib

Reply