<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic CIM Monitoring for Temperature ESXi 5.x in ESXi Discussions</title>
    <link>https://communities.vmware.com/t5/ESXi-Discussions/CIM-Monitoring-for-Temperature-ESXi-5-x/m-p/433530#M34402</link>
    <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Hey Guys,&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;I am trying to monitor the Temperature Sensors via CIM Monitoring. I have been looking around the Class Hierarchy list (&lt;A href="https://www.vmware.com/support/developer/cim-sdk/smash/u2/ga/apirefdoc/CIM_ManagedElement.html" title="https://www.vmware.com/support/developer/cim-sdk/smash/u2/ga/apirefdoc/CIM_ManagedElement.html"&gt;https://www.vmware.com/support/developer/cim-sdk/smash/u2/ga/apirefdoc/CIM_ManagedElement.html&lt;/A&gt;) but it's not really getting me anywhere.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;My namespace is root/cimv2, and my Class is VMware_DiscreteSensor.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;What Property do I need to be looking in? HealthState? OperatingStatus?&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;If I could just get a exact text dump of the Sensor Reading (shown below) I would be set.&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper" image-alt="vmscap.PNG"&gt;&lt;img src="https://communities.vmware.com/t5/image/serverpage/image-id/51320iA53EBEA22291D3E9/image-size/large?v=v2&amp;amp;px=999" role="button" title="vmscap.PNG" alt="vmscap.PNG" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
    <pubDate>Thu, 17 Apr 2014 21:37:40 GMT</pubDate>
    <dc:creator>ParseMeHard</dc:creator>
    <dc:date>2014-04-17T21:37:40Z</dc:date>
    <item>
      <title>CIM Monitoring for Temperature ESXi 5.x</title>
      <link>https://communities.vmware.com/t5/ESXi-Discussions/CIM-Monitoring-for-Temperature-ESXi-5-x/m-p/433530#M34402</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Hey Guys,&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;I am trying to monitor the Temperature Sensors via CIM Monitoring. I have been looking around the Class Hierarchy list (&lt;A href="https://www.vmware.com/support/developer/cim-sdk/smash/u2/ga/apirefdoc/CIM_ManagedElement.html" title="https://www.vmware.com/support/developer/cim-sdk/smash/u2/ga/apirefdoc/CIM_ManagedElement.html"&gt;https://www.vmware.com/support/developer/cim-sdk/smash/u2/ga/apirefdoc/CIM_ManagedElement.html&lt;/A&gt;) but it's not really getting me anywhere.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;My namespace is root/cimv2, and my Class is VMware_DiscreteSensor.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;What Property do I need to be looking in? HealthState? OperatingStatus?&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;If I could just get a exact text dump of the Sensor Reading (shown below) I would be set.&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper" image-alt="vmscap.PNG"&gt;&lt;img src="https://communities.vmware.com/t5/image/serverpage/image-id/51320iA53EBEA22291D3E9/image-size/large?v=v2&amp;amp;px=999" role="button" title="vmscap.PNG" alt="vmscap.PNG" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Thu, 17 Apr 2014 21:37:40 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/ESXi-Discussions/CIM-Monitoring-for-Temperature-ESXi-5-x/m-p/433530#M34402</guid>
      <dc:creator>ParseMeHard</dc:creator>
      <dc:date>2014-04-17T21:37:40Z</dc:date>
    </item>
    <item>
      <title>Re: CIM Monitoring for Temperature ESXi 5.x</title>
      <link>https://communities.vmware.com/t5/ESXi-Discussions/CIM-Monitoring-for-Temperature-ESXi-5-x/m-p/433531#M34403</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Hi,&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;What type or brand of server is using by you?&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;BR&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Fri, 18 Apr 2014 04:58:41 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/ESXi-Discussions/CIM-Monitoring-for-Temperature-ESXi-5-x/m-p/433531#M34403</guid>
      <dc:creator>DavoudTeimouri</dc:creator>
      <dc:date>2014-04-18T04:58:41Z</dc:date>
    </item>
    <item>
      <title>Re: CIM Monitoring for Temperature ESXi 5.x</title>
      <link>https://communities.vmware.com/t5/ESXi-Discussions/CIM-Monitoring-for-Temperature-ESXi-5-x/m-p/433532#M34404</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;"...If I could just get a exact text dump of the Sensor Reading..."&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;IIRC, ESXi is using lm_sensors, so you can get the same reading as text...&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Fri, 18 Apr 2014 05:55:21 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/ESXi-Discussions/CIM-Monitoring-for-Temperature-ESXi-5-x/m-p/433532#M34404</guid>
      <dc:creator>JarryG</dc:creator>
      <dc:date>2014-04-18T05:55:21Z</dc:date>
    </item>
    <item>
      <title>Re: CIM Monitoring for Temperature ESXi 5.x</title>
      <link>https://communities.vmware.com/t5/ESXi-Discussions/CIM-Monitoring-for-Temperature-ESXi-5-x/m-p/433533#M34405</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;We build our own servers. This specific server:&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Intel S5520UR Motherboard&lt;/P&gt;&lt;P&gt;2x Intel Xeon E5 CPUs&lt;/P&gt;&lt;P&gt;Intel RS2BL080 RAID Card&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Everything is on the HCL, It's just not an HP/Dell/Lenovo.&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Mon, 21 Apr 2014 14:39:38 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/ESXi-Discussions/CIM-Monitoring-for-Temperature-ESXi-5-x/m-p/433533#M34405</guid>
      <dc:creator>ParseMeHard</dc:creator>
      <dc:date>2014-04-21T14:39:38Z</dc:date>
    </item>
    <item>
      <title>Re: CIM Monitoring for Temperature ESXi 5.x</title>
      <link>https://communities.vmware.com/t5/ESXi-Discussions/CIM-Monitoring-for-Temperature-ESXi-5-x/m-p/433534#M34406</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;I figured it out guys.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;I set my CIM Target Namespace to root/cimv2&lt;/P&gt;&lt;P&gt;Class: CIM_NumericSensor&lt;/P&gt;&lt;P&gt;Property: CurrentReading&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Then I spent the last two hours testing each Instance. I'm pretty sure the instance's are based upon the Motherboard, but for the Intel S5520UR, here are my results:&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='16.0.32.99' system board 1 bb +1.1v IOH&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='17.0.32.99' system board 1 bb +1.1v p2 vccp&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='18.0.32.99' power supply 2 ps2 power in&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='19.0.32.99' system board 2 mem p1 therm margin&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='20.0.32.99' system board 1 bb +1.5 p2 ddr3&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='21.0.32.99' system board 1 bb +1.8v aux&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='22.0.32.99' ???&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='23.0.32.99' System board 1 bb +3.3v stby&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='24.0.32.99' system board 1 bb +3.3v+&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='25.0.32.99' system board 1 bb +5.0v&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='26.0.32.99' ???&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='27.0.32.99' system board 1 bb +12.0v&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='28.0.32.99' system board 1 bb -12.0v&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='32.0.32.99' system board 1 basebnoard temp &lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='33.0.32.99' front panel board 1 front panel temp&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='34.0.32.99' system board 1 IOH therm margin&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='35.0.32.99' system board 1 mem p1 therm margin&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='36.0.32.99' system board 2 mem p2 therm margin&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='49.0.32.99' fan device 2 system fan 2&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='51.0.32.99' fan device 4 system fan 4&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='56.0.32.99' fan device 5 system fan 5&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='82.0.32.99' power supply 1 ps1 power in&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='83.0.32.99' ??? power supply 2 ps2 curr out&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='84.0.32.99' ??? system board 1 mem p1 therm margn&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='85.0.32.99' ??? system board 2 mem p2 therm margn&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='86.0.32.99' power supply 1 ps1 temprature&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='87.0.32.99' power supply 2 ps2 temprature&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='98.0.32.99' processor 1 p1 therm margin&lt;/P&gt;&lt;P&gt;OMC_NumericSensor;DeviceID='99.0.32.99' processor 2 p2 therm margin&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Figured I'd post in case someone was searching Google.&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Tue, 22 Apr 2014 21:34:44 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/ESXi-Discussions/CIM-Monitoring-for-Temperature-ESXi-5-x/m-p/433534#M34406</guid>
      <dc:creator>ParseMeHard</dc:creator>
      <dc:date>2014-04-22T21:34:44Z</dc:date>
    </item>