PROFILE FOR STORAGE SUBSYSTEM: TEMPSAN01 (Tue Dec 13 09:12:29 EST 2011) SUMMARY------------------------------ Number of controllers: 2 High performance tier controllers: Disabled Number of arrays: 1 RAID 6: Enabled Total number of logical drives used: 4 Number of standard logical drives: 3 Number of access logical drives: 1 Total number of logical drives allowed: 512 Drive Limit Management: Number of drive slots discovered: 24 Number of drive slots allowed: 96 FlashCopy Logical Drives: Enabled Number of flashcopies used: 0 Number of flashcopies allowed: 2 Number of flashcopies allowed per base logical drive: 2 Solid State Disk Support: Disabled Number of drives used: 0 Number of drives allowed: 0 Enhanced Remote Mirroring (ERM): Disabled/Deactivated Number of mirrors used: 0 Number of mirrors allowed: 0 VolumeCopy: Disabled Number of copies used: 0 Number of copies allowed: 0 Number of drives: 12 Mixed drive types: Enabled Current media type(s): Hard Disk Drive (12) Current interface type(s): Serial Attached SCSI (SAS) (12) Total hot spare drives: 1 Standby: 1 In use: 0 Full Disk Encryption: Disabled Security key identifier: None Storage Partitioning: Enabled Number of partitions used: 2 Number of partitions allowed: 4 Number of logical drives allowed per partition: 256 Access logical drive: LUN 31,31,31 (see Mappings section for details) Default host OS: Windows Server 2003/Server 2008 Clustered (Host OS index 3) Current configuration Firmware version: 07.77.20.00 NVSRAM version: N1746D35R0777V05 SMW version: 10.77.G5.14 Pending configuration Staged firmware download supported: Yes Firmware version: None NVSRAM version: None Transferred on: None NVSRAM configured for batteries: Yes Start cache flushing at (in percentage): 80 Stop cache flushing at (in percentage): 80 Cache block size (in KB): 4 Media scan frequency (in days): 30 Failover alert delay (in minutes): 5 Feature enable identifier: 3032363133203130313632204E01F1EA Feature pack: Base Feature pack submodel ID: 137 Storage Subsystem world-wide identifier (ID): 60080E5000235C6C000000004E01F1E2 CONTROLLERS------------------------------ Number of controllers: 2 Controller in Enclosure 99, Slot A Status: Online Current configuration Firmware version: 07.77.20.00 Appware version: 07.77.20.00 Bootware version: 07.77.20.00 NVSRAM version: N1746D35R0777V05 Pending configuration Firmware version: None Appware version: None Bootware version: None NVSRAM version: None Transferred on: None Model name: 2680 Board ID: 2660 Submodel ID: 137 Product ID: 1746 FAStT Revision: 1070 Replacement part number: 68Y8481 Part number: 45233-06 Serial number: SV12812508 Vendor: IBM Date of manufacture: 15 July 2011 Trunking supported: No Data Cache Total present: 752 MB Total used: 752 MB Processor cache: Total present: 272 MB Cache Backup Device Status: Optimal Type: SD flash drive Location: Controller A, Connector USB 1 Capacity: 7,639 MB Product ID: Not Available Part number: Not Available Serial number: a00f0bed Revision level: 10 Manufacturer: Lexar Date of manufacture: 1 July 2011 Host Interface Board Status: Optimal Location: Slot 1 Type: Fibre channel Number of ports: 4 Board ID: 0801 Replacement part number: 69Y2841 Part number: PN 69Y2841 Serial number: SN SV11907318 Vendor: VN IBM Date of manufacture: 1 May 2011 Date/Time: Tue Dec 13 09:13:32 EST 2011 Associated Logical Drives (* = Preferred Owner): TEMPExch2010*, TEMPSAN500Gb*, ESXiScratch* Controller DNS/Network name: target Remote login: Disabled Ethernet port: 1 Link status: Down MAC address: 00:80:e5:24:1e:12 Negotiation mode: Auto-negotiate Port speed: Unknown Duplex mode: Half duplex Network configuration: Static IP address: 192.168.128.101 Subnet mask: 255.255.255.0 Gateway: 10.44.60.1 Ethernet port: 2 Link status: Up MAC address: 00:80:e5:24:1e:13 Negotiation mode: Auto-negotiate Port speed: 100 Mbps Duplex mode: Full duplex Network configuration: Static IP address: 10.44.60.93 Subnet mask: 255.255.255.0 Gateway: 10.44.60.1 Drive interface: SAS Channel: 1 Port: 1 Status: Up Maximum data rate: 6 Gbps Current data rate: 6 Gbps Drive interface: SAS Channel: 2 Port: 2 Status: Up Maximum data rate: 6 Gbps Current data rate: 6 Gbps Host interface: SAS Host Interface Card(HIC): Channel: 1 Port: 1 Status: Down World-wide identifier: 50:08:0e:52:41:e1:20:00 Maximum data rate: 6 Gbps Current data rate: Not available Part type: LSISAS2116 revision 100,664,064 Host interface: SAS Host Interface Card(HIC): Channel: 2 Port: 2 Status: Down World-wide identifier: 50:08:0e:52:41:e1:20:04 Maximum data rate: 6 Gbps Current data rate: Not available Part type: LSISAS2116 revision 100,664,064 Host interface: Fibre Host Interface Card(HIC): Channel: 3 Current ID: Not applicable/0xFFFFFFFF Preferred ID: 2/0xE4 NL-Port ID: 0x010300 Maximum data rate: 8 Gbps Current data rate: 8 Gbps Data rate control: Auto Link status: Up Topology: Fabric Attach World-wide port identifier: 20:34:00:80:e5:24:1e:12 World-wide node identifier: 20:04:00:80:e5:24:1e:12 Part type: PM8032 revision 8 Host interface: Fibre Host Interface Card(HIC): Channel: 4 Current ID: Not applicable/0xFFFFFFFF Preferred ID: 3/0xE2 NL-Port ID: 0xFFFFFF Maximum data rate: 8 Gbps Current data rate: 8 Gbps Data rate control: Auto Link status: Down Topology: Not Available World-wide port identifier: 20:44:00:80:e5:24:1e:12 World-wide node identifier: 20:04:00:80:e5:24:1e:12 Part type: PM8032 revision 8 Host interface: Fibre Host Interface Card(HIC): Channel: 5 Current ID: Not applicable/0xFFFFFFFF Preferred ID: 4/0xE1 NL-Port ID: 0x010300 Maximum data rate: 8 Gbps Current data rate: 8 Gbps Data rate control: Auto Link status: Up Topology: Fabric Attach World-wide port identifier: 20:54:00:80:e5:24:1e:12 World-wide node identifier: 20:04:00:80:e5:24:1e:12 Part type: PM8032 revision 8 Host interface: Fibre Host Interface Card(HIC): Channel: 6 Current ID: Not applicable/0xFFFFFFFF Preferred ID: 5/0xE0 NL-Port ID: 0xFFFFFF Maximum data rate: 8 Gbps Current data rate: 8 Gbps Data rate control: Auto Link status: Down Topology: Not Available World-wide port identifier: 20:64:00:80:e5:24:1e:12 World-wide node identifier: 20:04:00:80:e5:24:1e:12 Part type: PM8032 revision 8 Controller in Enclosure 99, Slot B Status: Online Current configuration Firmware version: 07.77.20.00 Appware version: 07.77.20.00 Bootware version: 07.77.20.00 NVSRAM version: N1746D35R0777V05 Pending configuration Firmware version: None Appware version: None Bootware version: None NVSRAM version: None Transferred on: None Model name: 2680 Board ID: 2660 Submodel ID: 137 Product ID: 1746 FAStT Revision: 1070 Replacement part number: 68Y8481 Part number: 45233-06 Serial number: SV12915087 Vendor: IBM Date of manufacture: 15 July 2011 Trunking supported: No Data Cache Total present: 752 MB Total used: 752 MB Processor cache: Total present: 272 MB Cache Backup Device Status: Optimal Type: SD flash drive Location: Controller B, Connector USB 1 Capacity: 7,639 MB Product ID: Not Available Part number: Not Available Serial number: a00f1023 Revision level: 10 Manufacturer: Lexar Date of manufacture: 1 July 2011 Host Interface Board Status: Optimal Location: Slot 1 Type: Fibre channel Number of ports: 4 Board ID: 0801 Replacement part number: 69Y2841 Part number: PN 69Y2841 Serial number: SN SV12518591 Vendor: VN IBM Date of manufacture: 1 June 2011 Date/Time: Tue Dec 13 09:13:33 EST 2011 Associated Logical Drives (* = Preferred Owner): None Controller DNS/Network name: target Remote login: Disabled Ethernet port: 1 Link status: Down MAC address: 00:80:e5:24:35:f8 Negotiation mode: Auto-negotiate Port speed: Unknown Duplex mode: Half duplex Network configuration: Static IP address: 192.168.128.102 Subnet mask: 255.255.255.0 Gateway: 10.44.60.1 Ethernet port: 2 Link status: Up MAC address: 00:80:e5:24:35:f9 Negotiation mode: Auto-negotiate Port speed: 100 Mbps Duplex mode: Full duplex Network configuration: Static IP address: 10.44.60.94 Subnet mask: 255.255.255.0 Gateway: 10.44.60.1 Drive interface: SAS Channel: 1 Port: 1 Status: Up Maximum data rate: 6 Gbps Current data rate: 6 Gbps Drive interface: SAS Channel: 2 Port: 2 Status: Up Maximum data rate: 6 Gbps Current data rate: 6 Gbps Host interface: SAS Host Interface Card(HIC): Channel: 1 Port: 1 Status: Down World-wide identifier: 50:08:0e:52:43:5f:80:00 Maximum data rate: 6 Gbps Current data rate: Not available Part type: LSISAS2116 revision 100,664,064 Host interface: SAS Host Interface Card(HIC): Channel: 2 Port: 2 Status: Down World-wide identifier: 50:08:0e:52:43:5f:80:04 Maximum data rate: 6 Gbps Current data rate: Not available Part type: LSISAS2116 revision 100,664,064 Host interface: Fibre Host Interface Card(HIC): Channel: 3 Current ID: Not applicable/0xFFFFFFFF Preferred ID: 8/0xD9 NL-Port ID: 0x010400 Maximum data rate: 8 Gbps Current data rate: 8 Gbps Data rate control: Auto Link status: Up Topology: Fabric Attach World-wide port identifier: 20:35:00:80:e5:24:1e:12 World-wide node identifier: 20:04:00:80:e5:24:1e:12 Part type: PM8032 revision 8 Host interface: Fibre Host Interface Card(HIC): Channel: 4 Current ID: Not applicable/0xFFFFFFFF Preferred ID: 9/0xD6 NL-Port ID: 0xFFFFFF Maximum data rate: 8 Gbps Current data rate: 8 Gbps Data rate control: Auto Link status: Down Topology: Not Available World-wide port identifier: 20:45:00:80:e5:24:1e:12 World-wide node identifier: 20:04:00:80:e5:24:1e:12 Part type: PM8032 revision 8 Host interface: Fibre Host Interface Card(HIC): Channel: 5 Current ID: Not applicable/0xFFFFFFFF Preferred ID: 10/0xD5 NL-Port ID: 0x010400 Maximum data rate: 8 Gbps Current data rate: 8 Gbps Data rate control: Auto Link status: Up Topology: Fabric Attach World-wide port identifier: 20:55:00:80:e5:24:1e:12 World-wide node identifier: 20:04:00:80:e5:24:1e:12 Part type: PM8032 revision 8 Host interface: Fibre Host Interface Card(HIC): Channel: 6 Current ID: Not applicable/0xFFFFFFFF Preferred ID: 11/0xD4 NL-Port ID: 0xFFFFFF Maximum data rate: 8 Gbps Current data rate: 8 Gbps Data rate control: Auto Link status: Down Topology: Not Available World-wide port identifier: 20:65:00:80:e5:24:1e:12 World-wide node identifier: 20:04:00:80:e5:24:1e:12 Part type: PM8032 revision 8 ARRAYS------------------------------ Number of arrays: 1 Name: TEMPArray Status: Optimal Capacity: 2,788.959 GB RAID level: 5 Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Enclosure loss protection: No Security Capable: No Secure: No Current owner: Controller in slot A Associated logical drives and free capacity Logical Drive Capacity ESXiScratch 20.039 GB TEMPExch2010 1,228.799 GB TEMPSAN500Gb 500.000 GB Free Capacity: 1,040.120 GB Associated drives - present (in piece order) Enclosure Slot 99 1 99 2 99 3 99 4 99 5 99 6 99 7 99 8 99 9 99 10 99 11 STANDARD LOGICAL DRIVES------------------------------ SUMMARY Number of standard logical drives: 3 See other Logical Drives sub-tabs for premium feature information. NAME STATUS CAPACITY RAID LEVEL ARRAY LUN ACCESSIBLE BY MEDIA TYPE INTERFACE TYPE TEMPExch2010 Optimal 1,228.799 GB 5 TEMPArray 0 Host Group TEMPESX-Servers Hard Disk Drive Serial Attached SCSI (SAS) TEMPSAN500Gb Optimal 500.000 GB 5 TEMPArray 1 Host Group TEMPESX-Servers Hard Disk Drive Serial Attached SCSI (SAS) ESXiScratch Optimal 20.039 GB 5 TEMPArray 0 Host Group TEMPESXiHosts-Citrix Hard Disk Drive Serial Attached SCSI (SAS) DETAILS Logical Drive name: TEMPExch2010 Logical Drive status: Optimal Capacity: 1,228.799 GB Logical Drive ID: 60:08:0e:50:00:24:35:f8:00:00:0e:65:4e:dc:9d:1e Subsystem ID (SSID): 1 Associated array: TEMPArray RAID level: 5 LUN: 0 Accessible By: Host Group TEMPESX-Servers Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Enclosure loss protection: No Secure: No Preferred owner: Controller in slot A Current owner: Controller in slot A Segment size: 256 KB Capacity reserved for future segment size changes: Yes Maximum future segment size: 2,048 KB Modification priority: High Read cache: Enabled Write cache: Enabled Write cache without batteries: Disabled Write cache with mirroring: Enabled Flush write cache after (in seconds): 10.00 Dynamic cache read prefetch: Enabled Enable background media scan: Enabled Media scan with redundancy check: Disabled Pre-Read redundancy check: Disabled Logical Drive name: TEMPSAN500Gb Logical Drive status: Optimal Capacity: 500.000 GB Logical Drive ID: 60:08:0e:50:00:24:35:f8:00:00:0e:c8:4e:e1:a8:33 Subsystem ID (SSID): 2 Associated array: TEMPArray RAID level: 5 LUN: 1 Accessible By: Host Group TEMPESX-Servers Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Enclosure loss protection: No Secure: No Preferred owner: Controller in slot A Current owner: Controller in slot A Segment size: 128 KB Capacity reserved for future segment size changes: Yes Maximum future segment size: 2,048 KB Modification priority: High Read cache: Enabled Write cache: Enabled Write cache without batteries: Disabled Write cache with mirroring: Enabled Flush write cache after (in seconds): 10.00 Dynamic cache read prefetch: Enabled Enable background media scan: Enabled Media scan with redundancy check: Disabled Pre-Read redundancy check: Disabled Logical Drive name: ESXiScratch Logical Drive status: Optimal Capacity: 20.039 GB Logical Drive ID: 60:08:0e:50:00:24:1e:12:00:00:06:5e:4e:d7:65:b0 Subsystem ID (SSID): 0 Associated array: TEMPArray RAID level: 5 LUN: 0 Accessible By: Host Group TEMPESXiHosts-Citrix Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Enclosure loss protection: No Secure: No Preferred owner: Controller in slot A Current owner: Controller in slot A Segment size: 128 KB Capacity reserved for future segment size changes: Yes Maximum future segment size: 2,048 KB Modification priority: High Read cache: Enabled Write cache: Enabled Write cache without batteries: Disabled Write cache with mirroring: Enabled Flush write cache after (in seconds): 10.00 Dynamic cache read prefetch: Enabled Enable background media scan: Enabled Media scan with redundancy check: Disabled Pre-Read redundancy check: Disabled FLASHCOPY REPOSITORY LOGICAL DRIVES------------------------------ Number of flashcopy repositories: 0 FLASHCOPY LOGICAL DRIVES------------------------------ Number of flashcopy logical drives: 0 MISSING LOGICAL DRIVES------------------------------ Number of missing logical drives: 0 DRIVES------------------------------ SUMMARY Number of drives: 12 Current media type(s): Hard Disk Drive (12) Current interface type(s): Serial Attached SCSI (SAS) (12) BASIC: ENCLOSURE, SLOT STATUS CAPACITY MEDIA TYPE INTERFACE TYPE CURRENT DATA RATE PRODUCT ID FIRMWARE VERSION CAPABILITIES 99, 1 Optimal 279.396 GB Hard Disk Drive SAS 6 Gbps ST9300603SS B53B 99, 2 Optimal 279.396 GB Hard Disk Drive SAS 6 Gbps ST9300603SS B53B 99, 3 Optimal 279.396 GB Hard Disk Drive SAS 6 Gbps ST9300603SS B53B 99, 4 Optimal 279.396 GB Hard Disk Drive SAS 6 Gbps ST9300603SS B53B 99, 5 Optimal 279.396 GB Hard Disk Drive SAS 6 Gbps ST9300603SS B53B 99, 6 Optimal 279.396 GB Hard Disk Drive SAS 6 Gbps ST9300603SS B53B 99, 7 Optimal 279.396 GB Hard Disk Drive SAS 6 Gbps ST9300603SS B53B 99, 8 Optimal 279.396 GB Hard Disk Drive SAS 6 Gbps ST9300603SS B53B 99, 9 Optimal 279.396 GB Hard Disk Drive SAS 6 Gbps ST9300603SS B53B 99, 10 Optimal 279.396 GB Hard Disk Drive SAS 6 Gbps ST9300603SS B53B 99, 11 Optimal 279.396 GB Hard Disk Drive SAS 6 Gbps ST9300603SS B53B 99, 12 Optimal 279.396 GB Hard Disk Drive SAS 6 Gbps ST9300603SS B53B DRIVE CHANNELS (Controller A): ENCLOSURE, SLOT PREFERRED CHANNEL REDUNDANT CHANNEL 99, 1 1 2 99, 2 2 1 99, 3 1 2 99, 4 2 1 99, 5 1 2 99, 6 2 1 99, 7 1 2 99, 8 2 1 99, 9 1 2 99, 10 2 1 99, 11 1 2 99, 12 2 1 HOT SPARE COVERAGE: The following arrays are not protected: None - All arrays are protected Total hot spare drives: 1 Standby: 1 In use: 0 Standby drive at enclosure 99, slot 12 (SAS, 279.396 GB) Protects the following arrays: TEMPArray DETAILS Drive at Enclosure 99, Slot 1 Status: Optimal Mode: Assigned Raw capacity: 279.396 GB Usable capacity: 278.896 GB World-wide identifier: 50:00:c5:00:3a:11:f6:b3:00:00:00:00:00:00:00:00 Associated array: TEMPArray Port Channel 0 1 1 2 Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Drive path redundancy: OK Security Capable: No Secure: No Read/write accessible: Yes Security key identifier: Not Applicable Speed: 10,000 RPM Current data rate: 6 Gbps Product ID: ST9300603SS Drive Firmware Version: B53B Serial number: 6SE3RBPR0000B123KJV9 Manufacturer: IBM-ESXS Date of manufacture: 19 May 2011 Drive at Enclosure 99, Slot 2 Status: Optimal Mode: Assigned Raw capacity: 279.396 GB Usable capacity: 278.896 GB World-wide identifier: 50:00:c5:00:3a:2a:cb:3f:00:00:00:00:00:00:00:00 Associated array: TEMPArray Port Channel 0 2 1 1 Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Drive path redundancy: OK Security Capable: No Secure: No Read/write accessible: Yes Security key identifier: Not Applicable Speed: 10,000 RPM Current data rate: 6 Gbps Product ID: ST9300603SS Drive Firmware Version: B53B Serial number: 6SE3SNFQ0000B142HKBN Manufacturer: IBM-ESXS Date of manufacture: 24 May 2011 Drive at Enclosure 99, Slot 3 Status: Optimal Mode: Assigned Raw capacity: 279.396 GB Usable capacity: 278.896 GB World-wide identifier: 50:00:c5:00:3a:2b:c6:d7:00:00:00:00:00:00:00:00 Associated array: TEMPArray Port Channel 0 1 1 2 Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Drive path redundancy: OK Security Capable: No Secure: No Read/write accessible: Yes Security key identifier: Not Applicable Speed: 10,000 RPM Current data rate: 6 Gbps Product ID: ST9300603SS Drive Firmware Version: B53B Serial number: 6SE3TZGB0000B142KUA9 Manufacturer: IBM-ESXS Date of manufacture: 25 May 2011 Drive at Enclosure 99, Slot 4 Status: Optimal Mode: Assigned Raw capacity: 279.396 GB Usable capacity: 278.896 GB World-wide identifier: 50:00:c5:00:3a:15:db:9b:00:00:00:00:00:00:00:00 Associated array: TEMPArray Port Channel 0 2 1 1 Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Drive path redundancy: OK Security Capable: No Secure: No Read/write accessible: Yes Security key identifier: Not Applicable Speed: 10,000 RPM Current data rate: 6 Gbps Product ID: ST9300603SS Drive Firmware Version: B53B Serial number: 6SE3R4AT0000B141K0GG Manufacturer: IBM-ESXS Date of manufacture: 20 May 2011 Drive at Enclosure 99, Slot 5 Status: Optimal Mode: Assigned Raw capacity: 279.396 GB Usable capacity: 278.896 GB World-wide identifier: 50:00:c5:00:3a:28:f2:33:00:00:00:00:00:00:00:00 Associated array: TEMPArray Port Channel 0 1 1 2 Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Drive path redundancy: OK Security Capable: No Secure: No Read/write accessible: Yes Security key identifier: Not Applicable Speed: 10,000 RPM Current data rate: 6 Gbps Product ID: ST9300603SS Drive Firmware Version: B53B Serial number: 6SE3QKBG0000B142HFYC Manufacturer: IBM-ESXS Date of manufacture: 24 May 2011 Drive at Enclosure 99, Slot 6 Status: Optimal Mode: Assigned Raw capacity: 279.396 GB Usable capacity: 278.896 GB World-wide identifier: 50:00:c5:00:3a:29:91:d3:00:00:00:00:00:00:00:00 Associated array: TEMPArray Port Channel 0 2 1 1 Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Drive path redundancy: OK Security Capable: No Secure: No Read/write accessible: Yes Security key identifier: Not Applicable Speed: 10,000 RPM Current data rate: 6 Gbps Product ID: ST9300603SS Drive Firmware Version: B53B Serial number: 6SE3SPZB0000B141NBA8 Manufacturer: IBM-ESXS Date of manufacture: 24 May 2011 Drive at Enclosure 99, Slot 7 Status: Optimal Mode: Assigned Raw capacity: 279.396 GB Usable capacity: 278.896 GB World-wide identifier: 50:00:c5:00:3a:0a:78:1f:00:00:00:00:00:00:00:00 Associated array: TEMPArray Port Channel 0 1 1 2 Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Drive path redundancy: OK Security Capable: No Secure: No Read/write accessible: Yes Security key identifier: Not Applicable Speed: 10,000 RPM Current data rate: 6 Gbps Product ID: ST9300603SS Drive Firmware Version: B53B Serial number: 6SE3QQJA0000B141H02F Manufacturer: IBM-ESXS Date of manufacture: 18 May 2011 Drive at Enclosure 99, Slot 8 Status: Optimal Mode: Assigned Raw capacity: 279.396 GB Usable capacity: 278.896 GB World-wide identifier: 50:00:c5:00:3a:2b:7d:63:00:00:00:00:00:00:00:00 Associated array: TEMPArray Port Channel 0 2 1 1 Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Drive path redundancy: OK Security Capable: No Secure: No Read/write accessible: Yes Security key identifier: Not Applicable Speed: 10,000 RPM Current data rate: 6 Gbps Product ID: ST9300603SS Drive Firmware Version: B53B Serial number: 6SE3V1P70000B142L75C Manufacturer: IBM-ESXS Date of manufacture: 24 May 2011 Drive at Enclosure 99, Slot 9 Status: Optimal Mode: Assigned Raw capacity: 279.396 GB Usable capacity: 278.896 GB World-wide identifier: 50:00:c5:00:3a:2b:f6:73:00:00:00:00:00:00:00:00 Associated array: TEMPArray Port Channel 0 1 1 2 Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Drive path redundancy: OK Security Capable: No Secure: No Read/write accessible: Yes Security key identifier: Not Applicable Speed: 10,000 RPM Current data rate: 6 Gbps Product ID: ST9300603SS Drive Firmware Version: B53B Serial number: 6SE3TZT90000B141MLCN Manufacturer: IBM-ESXS Date of manufacture: 24 May 2011 Drive at Enclosure 99, Slot 10 Status: Optimal Mode: Assigned Raw capacity: 279.396 GB Usable capacity: 278.896 GB World-wide identifier: 50:00:c5:00:3a:2b:cb:ef:00:00:00:00:00:00:00:00 Associated array: TEMPArray Port Channel 0 2 1 1 Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Drive path redundancy: OK Security Capable: No Secure: No Read/write accessible: Yes Security key identifier: Not Applicable Speed: 10,000 RPM Current data rate: 6 Gbps Product ID: ST9300603SS Drive Firmware Version: B53B Serial number: 6SE3TZHS0000B142KS43 Manufacturer: IBM-ESXS Date of manufacture: 25 May 2011 Drive at Enclosure 99, Slot 11 Status: Optimal Mode: Assigned Raw capacity: 279.396 GB Usable capacity: 278.896 GB World-wide identifier: 50:00:c5:00:3a:2b:d5:93:00:00:00:00:00:00:00:00 Associated array: TEMPArray Port Channel 0 1 1 2 Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Drive path redundancy: OK Security Capable: No Secure: No Read/write accessible: Yes Security key identifier: Not Applicable Speed: 10,000 RPM Current data rate: 6 Gbps Product ID: ST9300603SS Drive Firmware Version: B53B Serial number: 6SE3TZQ80000B142LKLZ Manufacturer: IBM-ESXS Date of manufacture: 25 May 2011 Drive at Enclosure 99, Slot 12 Status: Optimal Mode: Hot spare standby Raw capacity: 279.396 GB Usable capacity: 278.896 GB World-wide identifier: 50:00:c5:00:3a:2c:a8:47:00:00:00:00:00:00:00:00 Associated array: None Port Channel 0 2 1 1 Media type: Hard Disk Drive Interface type: Serial Attached SCSI (SAS) Drive path redundancy: OK Security Capable: No Secure: No Read/write accessible: Yes Security key identifier: Not Applicable Speed: 10,000 RPM Current data rate: 6 Gbps Product ID: ST9300603SS Drive Firmware Version: B53B Serial number: 6SE3TVNY0000B142JE61 Manufacturer: IBM-ESXS Date of manufacture: 25 May 2011 DRIVE CHANNELS---------------------------- SUMMARY CHANNEL PORT STATUS 1 1 Optimal 2 2 Optimal DETAILS DRIVE CHANNEL 1 Port: 1 Status: Optimal Max. Rate: 6 Gbps Current Rate: 6 Gbps Rate Control: Switched DRIVE COUNTS Total # of attached drives: 12 Connected to: Controller A Attached drives: 12 Drive expansion enclosure: 99 (12 drives) CUMULATIVE ERROR COUNTS Controller A Baseline time set: 4/12/11 11:50:32 AM Sample period (days, hh:mm:ss): 8 days, 21:23:07 Controller detected errors: 5 Drive detected errors: 38 Timeout errors: 2 Total I/O count: 5002083 Controller B Baseline time set: 9/12/11 8:34:24 AM Sample period (days, hh:mm:ss): 4 days, 00:39:08 Controller detected errors: 1 Drive detected errors: 12 Timeout errors: 0 Total I/O count: 821536 DRIVE CHANNEL 2 Port: 2 Status: Optimal Max. Rate: 6 Gbps Current Rate: 6 Gbps Rate Control: Switched DRIVE COUNTS Total # of attached drives: 12 Connected to: Controller B Attached drives: 12 Drive expansion enclosure: 99 (12 drives) CUMULATIVE ERROR COUNTS Controller A Baseline time set: 4/12/11 11:50:32 AM Sample period (days, hh:mm:ss): 8 days, 21:23:07 Controller detected errors: 19 Drive detected errors: 25 Timeout errors: 5 Total I/O count: 4809397 Controller B Baseline time set: 9/12/11 8:34:24 AM Sample period (days, hh:mm:ss): 4 days, 00:39:08 Controller detected errors: 1 Drive detected errors: 13 Timeout errors: 0 Total I/O count: 873291 ENCLOSURES------------------------------ Controller/Drive Expansion Enclosure 99 Overall Component Information Enclosure path redundancy: OK Current drive types: SAS Part number: PN 69Y0259 Serial number: SN SX13402140 Vendor: VN IBM Date of manufacture: 1 August 2011 Batteries Detected: 2 Battery status: Optimal Location: Controller A Age: 11 days Days until replacement: Not applicable Last learn cycle: 7 December 2011 Next learn cycle: 1 February 2012 Weeks between learn cycles: 8 Part number: PN 69Y2926 Serial number: SN SU13091743A1 Vendor: VN IBM Date of manufacture: 1 August 2011 Battery status: Optimal Location: Controller B Age: 11 days Days until replacement: Not applicable Last learn cycle: 7 December 2011 Next learn cycle: 1 February 2012 Weeks between learn cycles: 8 Part number: PN 69Y2926 Serial number: SN SU13091382A1 Vendor: VN IBM Date of manufacture: 1 August 2011 SFPs Detected: 4 SFP status: Optimal Attached to: Host-side of controller A Location: Host Card 1, Channel 3 Supported data rate(s): 2 Gbps, 4 Gbps, 8 Gbps Link length: Short Connector: LC Transmitter type: Shortwave Laser w/o OFC Transmission media: TM Multi-mode 62.5m(M6) IEEE company ID: 00 90 65 Revision: A Part number: FTLF8528P2BCV-ID Serial number: YH10RVB6R2TE Vendor: IBM-49Y4123 Date of manufacture: 24 June 2011 SFP status: Optimal Attached to: Host-side of controller A Location: Host Card 1, Channel 5 Supported data rate(s): 2 Gbps, 4 Gbps, 8 Gbps Link length: Short Connector: LC Transmitter type: Shortwave Laser w/o OFC Transmission media: TM Multi-mode 62.5m(M6) IEEE company ID: 00 90 65 Revision: A Part number: FTLF8528P2BCV-ID Serial number: YH10RVB6R5RD Vendor: IBM-49Y4123 Date of manufacture: 24 June 2011 SFP status: Optimal Attached to: Host-side of controller B Location: Host Card 2, Channel 3 Supported data rate(s): 2 Gbps, 4 Gbps, 8 Gbps Link length: Short Connector: LC Transmitter type: Shortwave Laser w/o OFC Transmission media: TM Multi-mode 62.5m(M6) IEEE company ID: 00 90 65 Revision: A Part number: FTLF8528P2BCV-ID Serial number: YH10RVB6R2MP Vendor: IBM-49Y4123 Date of manufacture: 24 June 2011 SFP status: Optimal Attached to: Host-side of controller B Location: Host Card 2, Channel 5 Supported data rate(s): 2 Gbps, 4 Gbps, 8 Gbps Link length: Short Connector: LC Transmitter type: Shortwave Laser w/o OFC Transmission media: TM Multi-mode 62.5m(M6) IEEE company ID: 00 90 65 Revision: A Part number: FTLF8528P2BCV-ID Serial number: YH10RVB6R2MX Vendor: IBM-49Y4123 Date of manufacture: 24 June 2011 Power-Fan CRUs Detected: 2 Power-fan CRU (Left) status: Optimal Part number: PN 69Y0201 Serial number: SN 113101637 Vendor: VN IBM Date of manufacture: 1 August 2011 Power-fan CRU (Right) status: Optimal Part number: PN 69Y0201 Serial number: SN 113101641 Vendor: VN IBM Date of manufacture: 1 August 2011 Power Supplies Detected: 2 Power supply status: Optimal Location: Left Part number: PN 69Y0201 Serial number: SN 113101637 Vendor: VN IBM Date of manufacture: 1 August 2011 Power supply status: Optimal Location: Right Part number: PN 69Y0201 Serial number: SN 113101641 Vendor: VN IBM Date of manufacture: 1 August 2011 Fans Detected: 4 Fan Status: Optimal Location: Left Fan Status: Optimal Location: Left Fan Status: Optimal Location: Right Fan Status: Optimal Location: Right Temperature Sensors Detected: 6 Temperature sensor status: Optimal Location: Controller A, Slot 1 Temperature sensor status: Optimal Location: Controller A, Slot 2 Temperature sensor status: Optimal Location: Controller B, Slot 1 Temperature sensor status: Optimal Location: Controller B, Slot 2 Temperature sensor status: Optimal Location: Power-fan CRU (Left) Temperature sensor status: Optimal Location: Power-fan CRU (Right) MAPPINGS (Storage Partitioning - Enabled (2 of 4 used))------------------- Logical Drive Name LUN Controller Accessible by Logical Drive status Access Logical Drive 31 A,B Default Group Optimal Access Logical Drive 31 A,B Host Group TEMPESX-Servers Optimal TEMPExch2010 0 A Host Group TEMPESX-Servers Optimal TEMPSAN500Gb 1 A Host Group TEMPESX-Servers Optimal Access Logical Drive 31 A,B Host Group TEMPESXiHosts-Citrix Optimal ESXiScratch 0 A Host Group TEMPESXiHosts-Citrix Optimal TOPOLOGY DEFINITIONS STORAGE SUBSYSTEM Default type: Windows Server 2003/Server 2008 Clustered Default Group Host Group: TEMPESXiHosts-Citrix Host: TEMPESXi1 Host type: VMWARE Interface type: Fibre Channel Host port identifier: 10:00:00:05:1e:fb:ce:ec Alias: TEMPESXi1-vmhba7 Host port identifier: 10:00:00:05:1e:fb:d2:92 Alias: TEMPESXi1-vmhba3 Host: TEMPESXi2 Host type: VMWARE Interface type: Fibre Channel Host port identifier: 10:00:00:05:1e:fb:d2:93 Alias: TEMPESXi2-vmhba7 Host port identifier: 10:00:00:05:1e:fb:ce:f1 Alias: TEMPESXi2-vmhba3 Host: TEMPESXi3 Host type: VMWARE Interface type: Fibre Channel Host port identifier: 10:00:00:05:1e:fb:d2:a1 Alias: TEMPESXi3-vmhba7 Host port identifier: 10:00:00:05:1e:fb:d2:96 Alias: TEMPESXi3-vmhba3 Host Group: TEMPESX-Servers Host: TEMPESX01 Host type: VMWARE Interface type: Fibre Channel Host port identifier: 10:00:00:05:1e:fb:ce:ee Alias: vmhba3 NVSRAM HOST TYPE DEFINITIONS NOTE: The following indexes are not used: 21 - 31 HOST TYPE ADT STATUS ASSOCIATED INDEX AIX Disabled 6 AIX (with Veritas DMP) Enabled 4 Base Disabled 0 HP-UX Enabled 7 HPXTPGS Disabled 17 IBM TS SAN VCE Enabled 12 IBM i Disabled 19 Irix Disabled 10 LNXAVT Enabled 5 LNXCLUSTER Disabled 13 Linux Disabled 18 MacOS Disabled 1 Netware Failover Disabled 11 Onstor Enabled 20 Solaris (with Veritas DMP) Enabled 14 Solaris (with or without MPXIO) Disabled 8 VMWARE Disabled 16 Windows Server 2003/Server 2008 Clustered Disabled 3 (Default) Windows Server 2003/Server 2008 Clustered (supports DMP) Enabled 15 Windows Server 2003/Server 2008 Non-Clustered Disabled 2 Windows Server 2003/Server 2008 Non-Clustered (supports DMP) Enabled 9