VMware Cloud Community
duhaas
Enthusiast
Enthusiast
Jump to solution

EMC Clarrion AX4 Array (ISCSI Multipathing Subnets)

Just wanted to get quick clarification from folks with setting up an EMC Clarrion array.  The array has two storage processors, each processor has two 1GB interfaces.  Should the config look like:

SPA1 - SUBNET1

SPA2 - SUBNET2

SPB1 - SUBNET1

SPB2 - SUBNET2

or

SPA1 - SUBNET1

SPA2 - SUBNET1

SPB1 - SUBNET2

SPB2 - SUBNET2

Trying to understand which of the two is accurate?

Tags (1)
Reply
0 Kudos
1 Solution

Accepted Solutions
vMario156
Expert
Expert
Jump to solution

It´s a while ago now I setup a Clarrion with iSCSI, but I´m pretty sure it was:

SPA1 - SUBNET1

SPA2 - SUBNET2

SPB1 - SUBNET1

SPB2 - SUBNET2

If I remember correct there have been also a good documentation in the manuals, which have been shipped with the Clarrion.

Regards,

Mario

Blog: http://vKnowledge.net

View solution in original post

Reply
0 Kudos
2 Replies
vMario156
Expert
Expert
Jump to solution

It´s a while ago now I setup a Clarrion with iSCSI, but I´m pretty sure it was:

SPA1 - SUBNET1

SPA2 - SUBNET2

SPB1 - SUBNET1

SPB2 - SUBNET2

If I remember correct there have been also a good documentation in the manuals, which have been shipped with the Clarrion.

Regards,

Mario

Blog: http://vKnowledge.net
Reply
0 Kudos
duhaas
Enthusiast
Enthusiast
Jump to solution

Thanks for the feedback, and your corret, found a great emc KB article:

https://community.emc.com/docs/DOC-12813

Reply
0 Kudos