Hi All,
I wonder if anyone come accross issues as per below photos.
And another one.
All seems start appearing with latest ESXi 6.7 patch, even on fresh installation it works for a few days and then freezes with purple screen. However when I try to access datastore to retrieve dump files to investigate I cant access anything at all and only way forward is to reinstall everything.
Thanks
What hardware is ESXi running on here? And is this a lab/non-business environment?
what is the hardware :- Its Dell or HP server.
I am running ESXi 6.7 in testing environment for now until purple screens will be resolved.
In terms of hardware:
In terms of drivers:
In addition when ESXi freeze server running without any issues as when I look into BMC there are no issues or error messages with the hardware.
One of the PSODs referenced is due to an NVMe error, so is that drive updated with the most recent firmware supported by the HCL?
Yes, it has latest drivers from HCL and latest firmware on Intel nvme itself (QDV101D1 latest firmware version).
Basically ESXi deployed on usb and vcenter (latest update) on nvme.
Below I added dump file:
2019-03-24T06:47:46.272Z cpu4:2097832)World: 3015: PRDA 0x418041000000 ss 0x0 ds 0x10b es 0x10b fs 0x10b gs 0x0
2019-03-24T06:47:46.272Z cpu4:2097832)World: 3017: TR 0xfd8 GDT 0x451a255a1000 (0xfe7) IDT 0x418034762000 (0xfff)
2019-03-24T06:47:46.272Z cpu4:2097832)World: 3018: CR0 0x80010031 CR3 0x10b89da000 CR4 0x142768
2019-03-24T06:47:46.318Z cpu4:2097832)Backtrace for current CPU #4, worldID=2097832, fp=0x459a5906f880
2019-03-24T06:47:46.340Z cpu4:2097832) [45m [33;1mVMware ESXi 6.7.0 [Releasebuild-11675023 x86_64] [0m
#PF Exception 14 in world 2097832:intel-nvme-c IP 0x0 addr 0x0
PTEs:0x13019e027;0x1322bd027;0x0;
2019-03-24T06:47:46.341Z cpu4:2097832)cr0=0x8001003d cr2=0x0 cr3=0x60c000 cr4=0x10216c
2019-03-24T06:47:46.341Z cpu4:2097832)frame=0x451a0ed1bb90 ip=0x0 err=16 rflags=0x10246
2019-03-24T06:47:46.341Z cpu4:2097832)rax=0x0 rbx=0x459a5906f580 rcx=0x451a0ed1bc9c
2019-03-24T06:47:46.342Z cpu4:2097832)rdx=0xe00fe00050000 rbp=0x459a5906f880 rsi=0x2
2019-03-24T06:47:46.342Z cpu4:2097832)rdi=0x459a5906f580 r8=0x0 r9=0x400a9
2019-03-24T06:47:46.342Z cpu4:2097832)r10=0x0 r11=0x43084bce0158 r12=0x43084bcdfdd0
2019-03-24T06:47:46.342Z cpu4:2097832)r13=0x43084bcdfdd0 r14=0xea26abcbe r15=0x459a5906f880
Coredump to disk.
2019-03-24T06:47:46.397Z cpu4:2097832)Slot 1 of 1 on device naa.2000acde48234567:9.
2019-03-24T06:47:46.397Z cpu4:2097832)Dump: 474: Using dump slot size 2684354560.
2019-03-24T06:47:46.400Z cpu4:2097832)Dump: 2845: Using dump buffer size 98304
INtel nvme_____________________xxxxxxxxxxxxxxxx__00000001" failed H:0x0 D:0x2 P:0x0 Valid sense
2019-03-23T04:30:04.698Z cpu3:2097832)data: 0x5 0x0 0x0.
2019-03-23T04:30:12.461Z cpu4:2099698 opID=82017d84)World: 11943: VC opID 53b1b339 maps to vmkernel opID 82017d84
[7m2019-03-23T04:30:12.461Z cpu4:2099698 opID=82017d84)WARNING: NetDVS: 6586: Failed to sync data from client com.vmware.common.port.statistics [0m
2019-03-24T06:47:46.343Z cpu4:2097832)@BlueScreen: #PF Exception 14 in world 2097832:intel-nvme-c IP 0x0 addr 0x0
PTEs:0x13019e027;0x1322bd027;0x0;
2019-03-24T06:47:46.343Z cpu4:2097832)Code start: 0x418034600000 VMK uptime: 1:13:10:06.632
2019-03-24T06:47:46.347Z cpu4:2097832)base fs=0x0 gs=0x418041000000 Kgs=0x0
2019-03-24T06:47:46.347Z cpu4:2097832)vmkernel 0x0 .data 0x0 .bss 0x0
2019-03-24T06:47:46.347Z cpu4:2097832)chardevs 0x418034d31000 .data 0x417fc0000000 .bss 0x417fc0000440
2019-03-24T06:47:46.347Z cpu4:2097832)user 0x418034d39000 .data 0x417fc0400000 .bss 0x417fc0410a40
2019-03-24T06:47:46.347Z cpu4:2097832)vmci_v2_shim | 0x418036373000 .data 0x417fdee00000 .bss 0x417fdee00750 |
2019-03-24T06:47:46.347Z cpu4:2097832)nsxt-dvfilterUser | 0x418036374000 .data 0x417fdf200000 .bss 0x417fdf2000a0 |
Hi,
I have attached log above.