Site Recovery Manager Error with EMC VNX5100

Hello, We have implemented two VNX5100 Arrays and have configured VMware Site Recovery Manager 4.1.2 using the following components:

  • Windows 2008 R2 Std Server for SRM server
  • VMware Site Recovery Manager 4.1.2
  • EMC Site Recovery Adapter for Mirrorview 1.4.0.16
  • Solutions Enabler 7.3.20 x86

The SRM servers are linked, and can see the LUNs presented by the consistency group through the Site Recovery Adapter.

However when I try to test the recovery plan I get errors. The logs show:

  • Mirror of VMFS4_REPLICATION(ConsistancyGroup: Group of WOKING REPLICATION Array: CKM00113100706) image: 00003 does not have an inactive snapshot with substring "VMWARE_SRM_SNAP". It is possible that the LUN is already testFailedover. Excluding the group from test failover.

  • DoClarSync ] ClarSync(SyncType:64) failed for CKM00113100706.. Error Details: The requested feature is not supported for this Enginuity or SYMAPI version
  • Unspecified error HRESULT:0x80004005

It seems that the requested feature error could be relevant. Does anyone have any suggestions / insights on this?

Thanks

Damian Davis

Tags (4)
Reply
0 Kudos
2 Replies
Damian_Davis
Enthusiast
Enthusiast

Could this indicate that the array is not supporting SnapView or modern equivalent and is therefore unable to run in test mode as the snap cannot be generated

Alternatively is this failure because the snap needs to be manually generated?

Damian Davis

Reply
0 Kudos
Damian_Davis
Enthusiast
Enthusiast

Indeed the issue was because the customer did not purchase the local protection pack. Case closed..