Hello!
Please help me to solve the problem:
While I run the test of recovery plan, i got an error:
Prepare Storage for Test: Non-fatal error information reported during execution of SRA: Failed to create lun snapshots.
Some information about my infrastructure:
SiteA:
vCenter 4.1 U1
ESX 4.1 U1
SRM 4.1.1
SRA - IBMSVCSRA_v1.20.10713
IBM Storwize V7000 - (Firmware version 6.1.0.7)
SiteB:
vCenter 4.1 U1
ESX 4.1 U1
SRM 4.1.1
SRA - IBMSVCSRA_v1.20.10713
IBM Storwize V7000 - (Firmware version 6.1.0.7)
To configure SRM i use this guide: http://www-03.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/WP101765
DatastoreA replicated from SiteA to SiteB (used Global Mirror - asyhronious replication). Status of replication: Consistent Synchronized.
Connection between SRM servers work fine, Array Manager on SiteA configured successfully, Array Manager on SiteB configuration finished with warning: Unable to display datastore groups. Replicated devices could not be matched with datastores in the inventory, Inventory Mapping on SiteA configured successfully, Inventory Mapping on SiteB not configured, Recovery Plan on SiteB created successfully.
Replicated LUN mapped to ESX on SiteB. In storage adapters configuration window (vSphere Client) this LUN is listed as device, but VMFS from replicated LUN not listed in storage configuration windows as Datastore.
Attache log file from SRM.
Thank for your help!
Hi,
I don't have any experience with IBM storage, but replicated LUN should not be mapped to ESX hosts at recovery site (site B). SRM should do the mapping when you perform a failover (or create and map the snapshots during test).
Check once again your SRA configuration. I believe you have missed something.
Michael.
Hi,
I don't have any experience with IBM storage, but replicated LUN should not be mapped to ESX hosts at recovery site (site B). SRM should do the mapping when you perform a failover (or create and map the snapshots during test).
Check once again your SRA configuration. I believe you have missed something.
Michael.
I unmaped recoverd LUN from ESX at recovery site (SiteB), but still have an error.
Plz ensure the zoning configured correctly at Site B.
Regards
Manick
Zoning configured correctly at Site B: ESX is booted from SAN, LUN with ESX installation and LUN with replicated VMFS Datastore are on the same Storwize at siteB.
VMware SRM Advanced Settings -> SAN Provider - SanProvider.CommandTimeout was 300, I have changed it to 1800, and SRM start work fine.
HI,
Is your SRM configuration still active and running with V7000 ? did you upgrade your V7000 firmware code,SRA and SRM version to current ?
Regards,
Visak