SRM 6.1 test failover error

Hi,

I'm getting below error when I'm running the test fail over for all the recovery plan.

Failed to create snapshot of replica device 000D1. SRA command 'testFailoverStart' failed for device '000D1'. An error occurred while performing testfailover start operation. Please check EmcSrdfSra log file.

Below is my setup

Main Site:

Vcenter 6.0 (VM)

SRM (6.1) (VM)

SRA (6.2)

SRDF  (VMAX)

DR SITE:

Vcenter 6.0 (VM)

SRM (6.1) (VM)

SRA (6.2)

SRDF  (VMAX)

Regards,

Hakim. B

0 Kudos
1 Solution

Accepted Solutions
hbhungra
Enthusiast
Enthusiast
Jump to solution

Issue has been resolved after manually entered the pairing information into Emcsrdfsratestfailoverconfig.xml.