Hi!!
we have a error with a test failover with 3 Luns: Error: Failed to recover datastore: Failed to failover LUN'60:06:01:60:10:E0:21:00:BA:EF:4E:AA:1D:CE:DD:11'.
We have SRM 1.0SRA1.2.0.4Clario CX4+Mirrorview A/S and SnapView for the Test Failover.
Failed to resolve 1 device locators for shadow VM 'shadow-vm-12488':
(vmodl.MethodFault) [
(dr.san.fault.RecoveredDatastoreNotFound) {
datastore = (dr.vimext.SanProviderDatastoreLocator) {
primaryUrl = "sanfs://vmfs_uuid:497f4278-55078d7f-9358-0022193fa023/",
reason = (dr.san.fault.LunFailoverFailed) {
key = "60:06:01:60:10:E0:21:00:BA:EF:4E:AA:1D:CE:DD:11",
Please can you help us?
Can you please attach the full log files of both the protected and recovery sites. By the way, there's a new version of SRM available and there are already three patches. Might want to look into that as well.
Duncan
VMware Communities User Moderator | VCP | VCDX
-
If you find this information useful, please award points for "correct" or "helpful".
Hi,
same goes for the clarIIon SRA..the latest one is EMC_MirrorView_Site_Recovery_Adapter-1.3.0.4
make sure to also match the right Solution Enabler version..
also, in regards to the error itself..it looks to me as if the snapshot lun used for the failover TEST cannot found, probably due to wrong naming convention..
clariion in the SRM context needs to have the snapshot luns with a very specific naming convention, e.g VMWARE_SRM_SNAP.
Itzik Reich
Solutions Architect
VCP,VTSP,MCTS,MCITP,MCSE,CCA,CCNA
EMC²
where Information Lives
If you find this information useful, please award points for "correct" or "helpful".