Hi. We have this error: Error - Error creating test bubble image for group 'GID-a3c95885-e644-4ba2-a50a-5a31ddff7e7f' on VR Server 'localhost.localdom' (address '172.16.100.1'). Cannot determine datastore for datastore UUID '54646194-843dd393-8dcc-1cc1deecc908'.
We have SRM 5.5.
Hi Cloomger,
This error is reported by VRMS when VR server DB points to datastore identifier value that can not be found in vCenter Server (by looking at all datastores in the datacenter of the replica, and inspecting DatastoreHostMount.mountInfo.mount properties, you can check these through vCenter MOB).
Has the LUN or host holding the replica target disks been disconnected and re-connected/re-added to vCenter Server?
Please file an SR, so that the VMware support team can look into support bundles of VR, vCenter and ESXi to diagnose what is the issue with the UUID value of the target datastore.
Regards,
Martin
Yes, we have reconnect LUN and run replication again, but replication good and test again error
Any body have ideas?