VMware Cloud Community
ruddy001
Contributor
Contributor

Dell Equallogic Invalid array management system credentials reported by the script

I have 2 Equallogic arrays replicating 2 LUNS.

ESX 3.5 with SRM 1.1

I have installed the SRA on both the primary and the DR sites.

The setup of SRA on the primary site went fine. Setup the recover plan on the DR side Fine.

When I run a test I get the following error in the log:

The scripts returned an error, leaving the temporary file 'C:\WINDOWS\TEMP\vmware-SYSTEM\dr-sanprovider0'

Invalid array management system credentials reported by the script

Failed to create lun snapshots: Unexpected MethodFault (dr.san.fault.AuthenticationFault) {

dynamicType = ,

command = "testFailover",

msg = ""

Reply
0 Kudos
1 Reply
ruddy001
Contributor
Contributor

Ok I figured it out. I was pointing to the Ethernet ip address of the DR array instead of the group IP address. All set now.

Reply
0 Kudos