Hello.
HP ProLiant ML110G6, Smart Aray P410, VMware-ESXi-6.0.0-Update3-9313334-HPE-preGen9-600.9.8.5.4-Sep2018 - OK
I tried to update to VMware-ESXi-6.5.0-Update3-14990892-HPE-preGen9-650.U3.9.6.10.1-Dec2019, updated successfully, but problems started when accessing the storage starts to hang, because of this I can’t add in vcenter.
I tried to put the system on USB Flash, everything is fine, but when I access the storage on the Smart Aray P410 it starts to hang, help with advice.
I downloaded the latest image (VMware-ESXi-6.5.0-Update3-14990892-HPE-preGen9-650.U3.9.6.10.1-Dec2019), everything was successfully installed and working successfully.
I tried the VMware_supermicro-ESXi-6.5.0-3.108.14990892_v21_supermicro image, everything works well, the storage does not hang to Vcenter connected, there was a problem, I could not configure hpssacli, it does not see the Smart Aray P410 controller, although I installed vib (hpsa, hpvsa, hpdsa).
Hello.
You should check the driver and the Frimware of the controller Smart Array P410 :
Driver hpsa version 6.0.0.84-1vmw or higher
Firmware version 6.64b
image VMware_supermicro-ESXi-6.5.0-3.108.14990892
Cheked firmware version SmartAray - OK v.6.64b
0000:20:00.0 RAID bus controller: HPE Smart Array P410 [vmhba2]
0000:20:00.0 103c:323a 103c:3243 5/ / A V nhpsa vmhba2
update hvsa - scsi-hpsa_6.0.0.114-1OEM.600.0.0.2494585.vib
setup - hpssacli-2.30.6.0-6.0.0.vib
-----
Сan't see the controller
Error: No controllers detected. Possible causes:
-----
Removed vib scsi-hpsa_6.0.0.114-1OEM.600.0.0.2494585.vib still sees storage, it feels like he uses another driver.
Setup vib scsi-hpsa_6.0.0.114-1OEM.600.0.0.2494585.vib - he would not install this driver, he would write an error that you cannot install online.
he uses
nhpsa 2.0.22-3vmw.650.2.50.8294253 VMW
how to change driver - hpsa? or it won't help?
I downloaded the latest image (VMware-ESXi-6.5.0-Update3-14990892-HPE-preGen9-650.U3.9.6.10.1-Dec2019), everything was successfully installed and working successfully.