VMware Cloud Community
virusvvv
Contributor
Contributor
Jump to solution

HP ProLiant ML110G6, Smart Aray P410 update esxi 6.5 - problem storage

Hello.
HP ProLiant ML110G6, Smart Aray P410, VMware-ESXi-6.0.0-Update3-9313334-HPE-preGen9-600.9.8.5.4-Sep2018 - OK
I tried to update to VMware-ESXi-6.5.0-Update3-14990892-HPE-preGen9-650.U3.9.6.10.1-Dec2019, updated successfully, but problems started when accessing the storage starts to hang, because of this I can’t add in vcenter.
I tried to put the system on USB Flash, everything is fine, but when I access the storage on the Smart Aray P410 it starts to hang, help with advice.

0 Kudos
1 Solution

Accepted Solutions
virusvvv
Contributor
Contributor
Jump to solution

I downloaded the latest image (VMware-ESXi-6.5.0-Update3-14990892-HPE-preGen9-650.U3.9.6.10.1-Dec2019), everything was successfully installed and working successfully.

 

 

View solution in original post

0 Kudos
5 Replies
virusvvv
Contributor
Contributor
Jump to solution

I tried the VMware_supermicro-ESXi-6.5.0-3.108.14990892_v21_supermicro image, everything works well, the storage does not hang to Vcenter connected, there was a problem, I could not configure hpssacli, it does not see the Smart Aray P410 controller, although I installed vib (hpsa, hpvsa, hpdsa).

0 Kudos
e_espinel
Virtuoso
Virtuoso
Jump to solution

Hello.
You should check the driver and the Frimware of the controller Smart Array P410 :
Driver hpsa version 6.0.0.84-1vmw or higher

Firmware version 6.64b

 

 

Enrique Espinel
Senior Technical Support on IBM, Lenovo, Veeam Backup and VMware vSphere.
VSP-SV, VTSP-SV, VTSP-HCI, VTSP
Please mark my comment as Correct Answer or assign Kudos if my answer was helpful to you, Thank you.
Пожалуйста, отметьте мой комментарий как Правильный ответ или поставьте Кудо, если мой ответ был вам полезен, Спасибо.
0 Kudos
virusvvv
Contributor
Contributor
Jump to solution

image VMware_supermicro-ESXi-6.5.0-3.108.14990892

Cheked firmware version SmartAray - OK v.6.64b

0000:20:00.0 RAID bus controller: HPE Smart Array P410 [vmhba2]

0000:20:00.0 103c:323a 103c:3243 5/ / A V nhpsa vmhba2

update hvsa - scsi-hpsa_6.0.0.114-1OEM.600.0.0.2494585.vib

setup - hpssacli-2.30.6.0-6.0.0.vib

-----

Сan't see the controller

Error: No controllers detected. Possible causes:

-----

Removed vib scsi-hpsa_6.0.0.114-1OEM.600.0.0.2494585.vib still sees storage, it feels like he uses another driver.

Setup vib scsi-hpsa_6.0.0.114-1OEM.600.0.0.2494585.vib - he would not install this driver, he would write an error that you cannot install online.

0 Kudos
virusvvv
Contributor
Contributor
Jump to solution

he uses 

nhpsa 2.0.22-3vmw.650.2.50.8294253 VMW

how to change driver - hpsa? or it won't help?

0 Kudos
virusvvv
Contributor
Contributor
Jump to solution

I downloaded the latest image (VMware-ESXi-6.5.0-Update3-14990892-HPE-preGen9-650.U3.9.6.10.1-Dec2019), everything was successfully installed and working successfully.

 

 

0 Kudos