I am running a single controller with 2x 4GB (that is what our FC switch is). I have 6x 450Gb 15k SAS Seagate drives. I am routing seeing performance based on "show vdisk-statistics" of around 170mb. This would seem normal for a single disk. However, when I add multiple disks to the vdisk, the performance stays the same. I am using IOMeter during the preparing disks section to measure throughput.
I am running ESXi 5.1U1. I have a host with a QLE 2462 and another host with a QLE2464 and am seeing the same performance.
Hi,
you check this setup:
- P2000G3 > Configuration > Advanced Settings > Cache
Sync Cache Mode = Immediate
- Volume ... > Configuration > Modify Volume Cache Settings
Write Policy = Write-Back
Hi,
When it comes to storage performance, it is important to consider the storage network topology. As I've seen your equipment, you only have one controller but have 2 FC switches, which is not ordinal network.
What kind of path selection policy do you use? Round robin, MRU(most recently use) or Fixed path?
The reason why I ask you is, it may be LUN ownership issue.
Best,
MAC
It is a single fiber channel switch.
Dennis Heim | Collaboration Solutions Architect
World Wide Technology, Inc. | +1 314-212-1814
<https://urldefense.proofpoint.com/v1/url?u=https://twitter.com/CollabSensei&k=oIvRg1%2BdGAgOoM1BIlLLqw%3D%3D%0A&r=FGyPC8ZSvBkKihkoeKgCmjuZI2qYJ8xvSchS1aM1v%2Fc%3D%0A&m=r13hYvPYqmE8ybZ%2BPs4jMtyuw5byiQUnby%2BlFhrjEpE%3D%0A&s=da693fc014af059ebde910b94307110603d17322393ac339fb153a4b739229ff>
<xmpp:dennis.heim@wwt.com>[cid:image003.png@01CF7E46.9EC0F510]<tel:+13142121814>[cid:image004.png@01CF7E46.9EC0F510]<sip:dennis.heim@wwt.com>