VMware Cloud Community
heimdm
Contributor
Contributor

HP P2000 G3 MSA Performance Issue

I am running a single controller with 2x 4GB (that is what our FC switch is). I have 6x 450Gb 15k SAS Seagate drives. I am routing seeing performance based on "show vdisk-statistics" of around 170mb. This would seem normal for a single disk. However, when I add multiple disks to the vdisk, the performance stays the same. I am using IOMeter during the preparing disks section to measure throughput.

I am running ESXi 5.1U1. I have a host with a QLE 2462 and another host with a QLE2464 and am seeing the same performance.

Reply
0 Kudos
3 Replies
vlho
Hot Shot
Hot Shot

Hi,

you check this setup:

- P2000G3 > Configuration > Advanced Settings > Cache

Sync Cache Mode = Immediate

- Volume ... > Configuration > Modify Volume Cache Settings

Write Policy = Write-Back

Reply
0 Kudos
macvirtual
Enthusiast
Enthusiast

Hi,

When it comes to storage performance, it is important to consider the storage network topology. As I've seen your equipment, you only have one controller but have 2 FC switches, which is not ordinal network.

What kind of path selection policy do you use? Round robin, MRU(most recently use) or Fixed path?

The reason why I ask you is, it may be LUN ownership issue.

Best,

MAC

Reply
0 Kudos
heimdm
Contributor
Contributor

It is a single fiber channel switch.

Dennis Heim | Collaboration Solutions Architect

World Wide Technology, Inc. | +1 314-212-1814

<https://urldefense.proofpoint.com/v1/url?u=https://twitter.com/CollabSensei&k=oIvRg1%2BdGAgOoM1BIlLLqw%3D%3D%0A&r=FGyPC8ZSvBkKihkoeKgCmjuZI2qYJ8xvSchS1aM1v%2Fc%3D%0A&m=r13hYvPYqmE8ybZ%2BPs4jMtyuw5byiQUnby%2BlFhrjEpE%3D%0A&s=da693fc014af059ebde910b94307110603d17322393ac339fb153a4b739229ff>

<xmpp:dennis.heim@wwt.com>[cid:image003.png@01CF7E46.9EC0F510]<tel:+13142121814>[cid:image004.png@01CF7E46.9EC0F510]<sip:dennis.heim@wwt.com>

Reply