VMware Cloud Community
thhg
Enthusiast
Enthusiast
Jump to solution

5.5 Install on Intel m.2 SSD

I have a new ThinkServer RD650 updated to current firmware, etc

When I try to install 5.5 fomr CD to the M.2 120GB SSD, it hangs at 9%

I re-tried this install again and still failed

and then again with a brand new identical Intel SSD (suspecting it was the SSD)

I then tried installing from CD to a USB stick and that worked fine

How can I tell what it's hanging on - there are no error messages

Steve

0 Kudos
1 Solution

Accepted Solutions
thhg
Enthusiast
Enthusiast
Jump to solution

SOLVED :

I tried a second Intel 540 M.2 card - no luck

I then installed a Samsung 850 EVO M.2

Everything installed fine

So it must be something to do with the Intel 540 series as I previously (just 2 months ago) used an Intel 535 M.2 card and it was fine

Hopes this helps someone else out

Steve

View solution in original post

0 Kudos
3 Replies
thhg
Enthusiast
Enthusiast
Jump to solution

There was an error both times - sorry

Unable to format VMFS volume datastore1 -  Exited with status : 1048320

0 Kudos
thhg
Enthusiast
Enthusiast
Jump to solution

SOLVED :

I tried a second Intel 540 M.2 card - no luck

I then installed a Samsung 850 EVO M.2

Everything installed fine

So it must be something to do with the Intel 540 series as I previously (just 2 months ago) used an Intel 535 M.2 card and it was fine

Hopes this helps someone else out

Steve

0 Kudos
grasshopper
Virtuoso
Virtuoso
Jump to solution

Glad you are up and running.  If you still want to test the other disk, consider installing the latest ESXi 6.x which may have the bits.  Though I don't use your hardware, I did have the same issue with certain M.2 SSD, for which I used the community vib by Adreas until the bits became native in ESXi 6.0 U2.

0 Kudos