VMware Horizon Community
Hozaifa_M
Contributor
Contributor

UEM and Outlook profiles

Hi all,

I have an Issue with UEM and Outlook profiles. I'm using instant clone desktop pool and the user must create his outlook profile each time he log-in.

I Run easy start and reditect the UEMprofile.

when I checked the Debug Logs for the user Archived logs, I found the following error.

2019-06-27 14:53:38.638 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Applications\Calculator.INI'

2019-06-27 14:53:35.162 [ERROR] Error 0x80070057 redirecting 'AppData' folder to '\\poc-uem\UEMprofiles\%username%\AppData' ('UEM.xml')

2019-06-27 14:53:35.911 [INFO ] Successfully redirected 'Desktop' folder to '\\poc-uem\UEMprofiles\%username%\Desktop' ('UEM.xml')

2019-06-27 14:53:36.443 [INFO ] Successfully redirected 'Documents' folder to '\\poc-uem\UEMprofiles\%username%\Documents' ('UEM.xml')

2019-06-27 14:53:36.711 [INFO ] Successfully redirected 'Downloads' folder to '\\poc-uem\UEMprofiles\%username%\Downloads' ('UEM.xml')

2019-06-27 14:53:36.991 [INFO ] Successfully redirected 'Favorites' folder to '\\poc-uem\UEMprofiles\%username%\Favorites' ('UEM.xml')

2019-06-27 14:53:37.159 [INFO ] Successfully redirected 'Music' folder to '\\poc-uem\UEMprofiles\%username%\Music' ('UEM.xml')

2019-06-27 14:53:37.522 [INFO ] Successfully redirected 'Pictures' folder to '\\poc-uem\UEMprofiles\%username%\Pictures' ('UEM.xml')

2019-06-27 14:53:38.006 [INFO ] Successfully redirected 'ProgramsMenu' folder to '\\poc-uem\UEMprofiles\%username%\Programs Menu' ('UEM.xml')

2019-06-27 14:53:38.190 [INFO ] Successfully redirected 'Videos' folder to '\\poc-uem\UEMprofiles\%username%\Videos' ('UEM.xml')

2019-06-27 14:53:38.359 [DEBUG] Skipping disabled UEM import task ('Delete Windows 5.x Start Menu.xml')

2019-06-27 14:53:38.363 [DEBUG] Skipping disabled UEM import task ('Delete Windows 6.x Start Menu.xml')

2019-06-27 14:53:38.391 [DEBUG] Skipping disabled UEM settings import ('Create 'Readme' file on Desktop.xml')

2019-06-27 14:53:38.396 [DEBUG] Skipping disabled UEM settings import ('Dutch.xml')

2019-06-27 14:53:38.399 [DEBUG] Skipping disabled UEM settings import ('German.xml')

2019-06-27 14:53:38.454 [DEBUG] Skipping disabled UEM drive hiding setting ('Hide some drives.xml')

2019-06-27 14:53:38.461 [INFO ] Collected ADMX-based settings to apply ('wallpaper.xml')

2019-06-27 14:53:38.535 [INFO ] Applied ADMX-based settings

2019-06-27 14:53:38.541 [INFO ] Collected App Volumes settings to apply for Offline Outlook Data File (.ost) ('OST.xml')

2019-06-27 14:53:38.542 [INFO ] Folder 'C:\SnapVolumesTemp\Writable' not found -- skipping writable folder configuration for Offline Outlook Data File (.ost)

2019-06-27 14:53:38.549 [DEBUG] Skipping disabled UEM triggered task ('Close Calculator at lock.xml')

2019-06-27 14:53:38.553 [INFO ] Configured message for trigger 'Workstation unlocked' ('Message at unlock.xml')

2019-06-27 14:53:38.556 [INFO ] Configured UEM refresh for trigger 'Workstation unlocked' ('Refresh Applications at unlock.xml')

2019-06-27 14:53:38.559 [INFO ] Configured UEM refresh for trigger 'Session reconnected' ('Refresh Printers at reconnect.xml')

2019-06-27 14:53:38.621 [INFO ] Config file '\\poc-uem\UEMConfig\general\Applications\Acrobat Reader.INI' added to DirectFlex cache

2019-06-27 14:53:38.638 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Applications\Calculator.INI'

2019-06-27 14:53:38.661 [INFO ] Config file '\\poc-uem\UEMConfig\general\Applications\Notepad.INI' added to DirectFlex cache

2019-06-27 14:53:38.679 [INFO ] Config file '\\poc-uem\UEMConfig\general\Applications\Paint.INI' added to DirectFlex cache

2019-06-27 14:53:38.696 [INFO ] Config file '\\poc-uem\UEMConfig\general\Applications\PaintDotNet.ini' added to DirectFlex cache

2019-06-27 14:53:38.713 [INFO ] Config file '\\poc-uem\UEMConfig\general\Applications\Remote Desktop Connection.INI' added to DirectFlex cache

2019-06-27 14:53:38.730 [INFO ] Config file '\\poc-uem\UEMConfig\general\Applications\VLC.ini' added to DirectFlex cache

2019-06-27 14:53:38.794 [INFO ] Config file '\\poc-uem\UEMConfig\general\Applications\Wordpad.INI' added to DirectFlex cache

2019-06-27 14:53:38.803 [DEBUG] Conditions: Evaluating condition set 'Microsoft Office 2016.xml'

2019-06-27 14:53:38.824 [DEBUG] Conditions: Check for path 'C:\Program Files (x86)\Microsoft Office\Office16' = true

2019-06-27 14:53:38.827 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Microsoft Office 2016\Access.ini'

2019-06-27 14:53:38.835 [DEBUG] Conditions: Condition set 'Microsoft Office 2016.xml' was previously evaluated to true

2019-06-27 14:53:38.838 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Microsoft Office 2016\Excel.ini'

2019-06-27 14:53:38.844 [INFO ] Skipping disabled config file '\\poc-uem\UEMConfig\general\Microsoft Office 2016\OneDrive for Business.ini'

2019-06-27 14:53:38.848 [DEBUG] Conditions: Condition set 'Microsoft Office 2016.xml' was previously evaluated to true

2019-06-27 14:53:38.850 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Microsoft Office 2016\OneNote.ini'

2019-06-27 14:53:38.857 [DEBUG] Conditions: Condition set 'Microsoft Office 2016.xml' was previously evaluated to true

2019-06-27 14:53:38.859 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Microsoft Office 2016\Outlook.ini'

2019-06-27 14:53:38.867 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Microsoft Office 2016\Outlooknew.INI'

2019-06-27 14:53:38.874 [DEBUG] Conditions: Condition set 'Microsoft Office 2016.xml' was previously evaluated to true

2019-06-27 14:53:38.876 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Microsoft Office 2016\PowerPoint.ini'

2019-06-27 14:53:38.882 [DEBUG] Conditions: Condition set 'Microsoft Office 2016.xml' was previously evaluated to true

2019-06-27 14:53:38.884 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Microsoft Office 2016\Project.ini'

2019-06-27 14:53:38.890 [DEBUG] Conditions: Condition set 'Microsoft Office 2016.xml' was previously evaluated to true

2019-06-27 14:53:38.892 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Microsoft Office 2016\Publisher.ini'

2019-06-27 14:53:38.899 [DEBUG] Conditions: Condition set 'Microsoft Office 2016.xml' was previously evaluated to true

2019-06-27 14:53:38.901 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Microsoft Office 2016\Shared Settings.ini'

2019-06-27 14:53:38.907 [DEBUG] Conditions: Condition set 'Microsoft Office 2016.xml' was previously evaluated to true

2019-06-27 14:53:38.909 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Microsoft Office 2016\Skype for Business.ini'

2019-06-27 14:53:38.915 [DEBUG] Conditions: Condition set 'Microsoft Office 2016.xml' was previously evaluated to true

2019-06-27 14:53:38.917 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Microsoft Office 2016\Visio.ini'

2019-06-27 14:53:38.924 [DEBUG] Conditions: Condition set 'Microsoft Office 2016.xml' was previously evaluated to true

2019-06-27 14:53:38.926 [INFO ] No profile archive to import for config file '\\poc-uem\UEMConfig\general\Microsoft Office 2016\Word.ini'

2019-06-27 14:53:38.934 [DEBUG] Conditions: Check for OS Windows 10 = true

3 Replies
DEMdev
VMware Employee
VMware Employee

Hi Hozaifa_M,

Your log file only contains path-based imports, which would explain why no settings are being saved... Did you configure FlexEngine to run from a logoff script?

Also, why exactly are you redirecting all those profile folders? It's fine to do that for the ones that contain user data, but redirecting AppData is typically not a great idea.

0 Kudos
Hozaifa_M
Contributor
Contributor

Thanks for your Reply,

we I've already configured the Log-off script, I don't need to redirect App Data, I was troubleshooting  only   Import\Export outlook profiles for VDI users with IC desktop pool.

also, I need to mention that I didn't configure Mandatory profile setting steps on the UEM procedures on tech zone articles.

the last point

what is the correct method to write the log-off script.

C:\Program Files\Immidio\Flex Profiles\FlexEngine.exe -s

or

"C:\Program Files\Immidio\Flex Profiles\FlexEngine.exe -s"

or

C:\Program Files\Immidio\Flex Profiles\FlexEngine.exe

and then ad -s on the parameter filed on the GP editor scripts console

0 Kudos
ijdemes
Expert
Expert

This depends on how you do the logoff. Are you using FlexEngine in a CMD/Batch script, then use the following in that file:

"C:\Program Files\Immidio\Flex Profiles\FlexEngine.exe" -s

Are you using FlexEngine.exe directly in a logoff GPO then use the following:

Script Name:

C:\Program Files\Immidio\Flex Profiles\FlexEngine.exe

Script Parameters:

-s


\\ Ivan
---
Twitter: @ivandemes
Blog: https://www.ivandemes.com