Hello! I'm trying to do a P2V conversion to a ESXi 6.0 host using the VMware standalone converter on a Windows 2012 server. After completing the C: drive, and starting a larger 1.8TB drive, the conversion fails with the following error:
FAILED: An error occurred during the conversion: 'BlockLevelVolumeCloneMgr::CloneVolume: Detected a write error during the cloning of volume \WindowsBitmapDriverVolumeId=[D4-6B-30-48-00-00-10-00-00-00-00-00]. Error: 37409 (type: 1, code:
2338)'
My ESXi host has over 12T local storage, with 8TB free. Has any seen this?
Any help would be appreciated!
If a conversion fails using the exact size of hard disks, decrease the size of the disks by at least 1MB. This forces VMware Converter to do a file level copy instead of a block level copy, which can be more successful if there are errors with the volume or if there are file-locking issues.
Make sure atleast 10% free disk space on the source drive.
Reference :
Troubleshooting checklist for VMware Converter (1016330) | VMware KB
If you found this or any other answer helpful, please consider the use of the Helpful to award points.
Best Regards,
Deepak Koshal
CNE|CLA|CWMA|VCP4|VCP5|CCAH
Hi,
Follow this article and let me know if any help needed :- https://masteringnutanix.com/2020/06/19/vmware-coverter-block-level-volume-clonemgrclonevolume-detec...