same trouble a some of old posts:

failed: Fault.ManagerDiskOpenFault.summary

i join my vmware-converter-server log

thank for your help

Reply
0 Kudos
7 Replies
patanassov
VMware Employee
VMware Employee

Server log is not very informative. Pls attach worker log; if P2V (powered on source) - agent log too.

Reply
0 Kudos
stdavid
Contributor
Contributor

here is the worker log

thks

Reply
0 Kudos
patanassov
VMware Employee
VMware Employee

OK, now please attach the agent's log. It is a P2V after all.

Regards

Reply
0 Kudos
stdavid
Contributor
Contributor

here is the agent log

Reply
0 Kudos
POCEH
VMware Employee
VMware Employee

Your error is:

2014-01-08T15:18:27.839+01:00 [00932 warning 'Default'] [,0] [NFC ERROR] NfcNewAuthdConnectionEx: Failed to connect to peer. Error: Failed to connect to server 192.168.70.1:902

You need to allow your physical machine to connect to the ESX at port 902.

HTH

Reply
0 Kudos
stdavid
Contributor
Contributor

i'm going to check if my fw allow that

thks

Reply
0 Kudos
stdavid
Contributor
Contributor

i have convert to local drive and import to my esx ( 3 NIC to the vcenter converter) too complicate !