VMware Cloud Community
yunleong
Contributor
Contributor

98% FAILED: A general system error occurred: Unknown exception. Win Svr 2003 SP2

We are trying to convert a Windows Server 2003 x64 SP2 machine and get this error at 98 percent

FAILED: A general system error occurred: Unknown exception.

The only reference I see in the log file is,

2015-09-25T18:07:50.032+08:00 warning vmware-converter-worker[04980] [Originator@6876 sub=Default] [,0] [NFC ERROR] NfcNetTcpWrite: bWritten: -1

2015-09-25T18:07:50.032+08:00 warning vmware-converter-worker[04980] [Originator@6876 sub=Default] [,0] [NFC ERROR] NfcSendMessage: send failed: NFC_NETWORK_ERROR

2015-09-25T18:07:50.032+08:00 warning vmware-converter-worker[04980] [Originator@6876 sub=Default] [,0] [NFC ERROR] NfcFssrvr_IO: failed to send io message

2015-09-25T18:07:50.032+08:00 info vmware-converter-worker[04980] [Originator@6876 sub=Default] Sysimgbase_DiskLib_Write failed with 'NBD_ERR_NETWORK_CONNECT' (error code:2338)

2015-09-25T18:07:50.032+08:00 warning vmware-converter-worker[03140] [Originator@6876 sub=Default] ERROR: Vmount library: Error 2338 while while writing to device

All log attached. Any help would be greatly appreciated.

Reply
0 Kudos
3 Replies
POCEH
VMware Employee
VMware Employee

Should be network problem, I hope temporary, the NFC errors begins with the following message:

2015-09-25T18:06:06.172+08:00 error vmware-converter-worker[04840] [Originator@6876 sub=task-1] VimConnectionHelper Keepalive to host 192.168.4.38 failed: An existing connection was forcibly closed by the remote host

Try to configure only your destination VM

HTH

Reply
0 Kudos