<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0) in VMware PowerCLI Discussions</title>
    <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923858#M27076</link>
    <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;I was doing something similar at one point, see&amp;nbsp; &lt;STRONG&gt;&lt;A _jive_internal="true" class="font-color-meta-light" href="https://communities.vmware.com/message/2583414#2583414" title="Link to reply #3"&gt;3.&lt;/A&gt;&amp;nbsp; &lt;A _jive_internal="true" class="font-color-meta-light" href="https://communities.vmware.com/message/2583414#2583414" name="&amp;amp;amp;lpos=apps_scodevmw : 85"&gt;Re: Power CLI script to find&amp;nbsp; pcislotnumer(UI number) in a windows guest OS&lt;/A&gt; &lt;/STRONG&gt; &lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;But I stumbled on the fact that I couldn't find any logic in the numbers that you get.&lt;/P&gt;&lt;P&gt;When you start adding/removing SCSI controllers, the number, which you covered by the Switch, can be all over the place.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;But if it works for, good find!&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
    <pubDate>Tue, 13 Sep 2016 11:49:24 GMT</pubDate>
    <dc:creator>LucD</dc:creator>
    <dc:date>2016-09-13T11:49:24Z</dc:date>
    <item>
      <title>Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923852#M27070</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Hi Folks &lt;img id="smileyhappy" class="emoticon emoticon-smileyhappy" src="https://communities.vmware.com/i/smilies/16x16_smiley-happy.png" alt="Smiley Happy" title="Smiley Happy" /&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;I am looking to get to the bottom to the bottom of matching VMWare hard disks to disks in Windows using WMI.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;So far all scripts I have found work with SCSI Controller 0, but it fails when trying to get details on SCSI Controller 1 and for some reason the details in WMI - it always incorrectly reports it as controller 0 even when its not.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;I found this article which is great, but surely there is a Windows WMI way to get this to compare?&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;&lt;A href="https://echohellowordl.blogspot.co.uk/2014/02/match-virtual-hard-disks-in-virtual.html" title="https://echohellowordl.blogspot.co.uk/2014/02/match-virtual-hard-disks-in-virtual.html"&gt;echo( "hello wordl" &lt;img class="lia-deferred-image lia-image-emoji" src="https://communities.vmware.com/html/@8D3AC78033E090809829B1C8262B7619/emoticons/1f61e.png" alt=":disappointed_face:" title=":disappointed_face:" /&gt; Match virtual hard disks in Virtual Center with their disk labels in Windows 2008&lt;/A&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;The other thing I was wondering was based on the article above, is it possible to get the location of the VMX file and read its contents into a variable so that you can match the &lt;STRONG&gt;"&lt;STRONG&gt;scsi1.pciSlotNumber"&lt;/STRONG&gt; &lt;/STRONG&gt;value to the number reported in WMI?&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;I have scoured the net and this is the closest thing I can find to unpicking this issue.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Any help would be greatly appreciated :smileygrin:&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Sat, 10 Sep 2016 23:46:55 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923852#M27070</guid>
      <dc:creator>Mike_Yazbeck</dc:creator>
      <dc:date>2016-09-10T23:46:55Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923853#M27071</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;This has been my Holy Grail since years :smileygrin:&lt;/P&gt;&lt;P&gt;And believe me, the author of that post is a bit optimistic with his claim of "foolproof" I'm afraid.&lt;/P&gt;&lt;P&gt;For example, try removing/adding hard disks, and this Location number will change, and with no logic to be detected so far.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;I still give my quest an occasional try, but I just don't seem to be making any progress :smileycry:&lt;/P&gt;&lt;P&gt;As a side-note, foolproof in my book, also means that the logic shall also work for VMs that run a Linux guest OS.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;But I keep trying to find a method.&lt;/P&gt;&lt;P&gt;Perhaps one day the light will shine :smileycool:&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Sun, 11 Sep 2016 04:55:04 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923853#M27071</guid>
      <dc:creator>LucD</dc:creator>
      <dc:date>2016-09-11T04:55:04Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923854#M27072</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;I can imagine :smileygrin:&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;I think I have managed to suss it out.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Although the author you are talking about that claimed his script was "fool proof" (which clearly isnt), he was actually on the right track.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;The solution is in fact a registry key! I will send some screenshots to explain tomorrow :smileygrin:&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;One of the main WMI properties for the disk drive is just a registry tree which can be broken down using "split".&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Hopefully when I get it all working, I can demonstrate :smileygrin:&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Watch this space &lt;img id="smileywink" class="emoticon emoticon-smileywink" src="https://communities.vmware.com/i/smilies/16x16_smiley-wink.png" alt="Smiley Wink" title="Smiley Wink" /&gt;&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Mon, 12 Sep 2016 20:20:51 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923854#M27072</guid>
      <dc:creator>Mike_Yazbeck</dc:creator>
      <dc:date>2016-09-12T20:20:51Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923855#M27073</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;I walked the registry path as well, some observations&lt;/P&gt;&lt;UL&gt;&lt;LI&gt;although you can find the number in there, there is no apparent logic to map the disk label to the number&lt;/LI&gt;&lt;LI&gt;by definition doesn't cover VMs that run a Linux guest OS&lt;/LI&gt;&lt;/UL&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Tue, 13 Sep 2016 04:45:50 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923855#M27073</guid>
      <dc:creator>LucD</dc:creator>
      <dc:date>2016-09-13T04:45:50Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923856#M27074</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;This is roughly how my code looks:&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;[Int64]$HKLM = "2147483650"&lt;/P&gt;&lt;P&gt;[String]$value = "UINumber"&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;$Reg_Query = Get-WmiObject -List "StdRegProv" -Namespace root\cimv2 -Computername $server -Credential $cred&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;ForEach ($LogicalDisk in $Win32_LogicalDisk)&lt;/P&gt;&lt;P&gt;{&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; $LogicalDiskToPartition = $Win32_LogicalDiskToPartition | Where-Object {$_.Dependent -eq $LogicalDisk.Path}&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; if ($LogicalDiskToPartition)&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; {&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; $DiskDriveToDiskPartition = $Win32_DiskDriveToDiskPartition | Where-Object {$_.Dependent -eq $LogicalDiskToPartition.Antecedent}&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; if ($DiskDriveToDiskPartition)&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; {&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; $DiskDrive = $Win32_DiskDrive | Where-Object {$_.__Path -eq $DiskDriveToDiskPartition.Antecedent}&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; if ($DiskDrive)&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; {&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; $WMI_VirtualDisk = "" | Select DeviceID, SCSIBus, SCSITargetId, Size, WinDisk, VolumeName&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; $WMI_VirtualDisk.DeviceID = $LogicalDisk.DeviceID&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; #$WMI_VirtualDisk.SCSIBus = $DiskDrive.SCSIBus 'Technically it does work, but only for SCSI controller 0&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; $WMI_VirtualDisk.SCSITargetId = $DiskDrive.SCSITargetId&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; $WMI_VirtualDisk.Size = [Math]::Round($DiskDrive.Size / 1GB)&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; $WMI_VirtualDisk.WinDisk = $DiskDrive.Index&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; $WMI_VirtualDisk.VolumeName = $LogicalDisk.VolumeName&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; #new code - works!&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; $PNPDeviceID = $DiskDrive.PNPDeviceID.Split("\")&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; $key = "SYSTEM\CurrentControlSet\Enum\$($PNPDeviceID[0])\$($PNPDeviceID[1])\$($PNPDeviceID[2])"&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; $SCSI_Controller = ($Reg_Query.GetDWORDValue($HKLM,$key,$value)).uvalue&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Switch ($SCSI_Controller) &lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; {&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; "32" {$SCSI_Controller = '1';Break}&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; "160" {$SCSI_Controller = '0';Break}&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; "256" {$SCSI_Controller = '1';Break}&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; "161" {$SCSI_Controller = '2';Break}&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; "224" {$SCSI_Controller = '3';Break}&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Default {$SCSI_Controller = '0';Break}&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; }&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; $WMI_VirtualDisk.SCSIBus = $SCSI_Controller&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; $WMI_DiskArray += $WMI_VirtualDisk&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; }&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; }&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; }&lt;/P&gt;&lt;P&gt;}&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Where I work we use a NetApp SAN solution. I dont think that that matters all too much, but I thought I would give you a heads up as you are likely to be using something very different &lt;img id="smileyhappy" class="emoticon emoticon-smileyhappy" src="https://communities.vmware.com/i/smilies/16x16_smiley-happy.png" alt="Smiley Happy" title="Smiley Happy" /&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;The $PNPDeviceID is a property of the $DiskDrive which essentially appears to be a registry key path which if you split, you can access the registry remotely using WMI, which works like a charm :smileygrin:&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;I literally just got this finished and working the way I want... hope it helps :smileygrin:&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Tue, 13 Sep 2016 11:13:29 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923856#M27074</guid>
      <dc:creator>Mike_Yazbeck</dc:creator>
      <dc:date>2016-09-13T11:13:29Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923857#M27075</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;By the way, I would like to add this is coded with Windows in mind not Linux.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;My script runs a menu system so that I can perform multiple functions independently.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Personally I recommend doing that here, and then calling a function from the menu that is specifically designed to talk to Windows and coding a separate function that talks to Linux :smileygrin:&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Tue, 13 Sep 2016 11:16:00 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923857#M27075</guid>
      <dc:creator>Mike_Yazbeck</dc:creator>
      <dc:date>2016-09-13T11:16:00Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923858#M27076</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;I was doing something similar at one point, see&amp;nbsp; &lt;STRONG&gt;&lt;A _jive_internal="true" class="font-color-meta-light" href="https://communities.vmware.com/message/2583414#2583414" title="Link to reply #3"&gt;3.&lt;/A&gt;&amp;nbsp; &lt;A _jive_internal="true" class="font-color-meta-light" href="https://communities.vmware.com/message/2583414#2583414" name="&amp;amp;amp;lpos=apps_scodevmw : 85"&gt;Re: Power CLI script to find&amp;nbsp; pcislotnumer(UI number) in a windows guest OS&lt;/A&gt; &lt;/STRONG&gt; &lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;But I stumbled on the fact that I couldn't find any logic in the numbers that you get.&lt;/P&gt;&lt;P&gt;When you start adding/removing SCSI controllers, the number, which you covered by the Switch, can be all over the place.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;But if it works for, good find!&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Tue, 13 Sep 2016 11:49:24 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923858#M27076</guid>
      <dc:creator>LucD</dc:creator>
      <dc:date>2016-09-13T11:49:24Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923859#M27077</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;I love the way you code, it so articulate :smileygrin:&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;I see, thats ashame &lt;img id="smileysad" class="emoticon emoticon-smileysad" src="https://communities.vmware.com/i/smilies/16x16_smiley-sad.png" alt="Smiley Sad" title="Smiley Sad" /&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;I've run my script against a couple servers and it seems to work - one of them was the primary exchange server and the other is clustered SQL server:&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper" image-alt="pastedImage_3.png"&gt;&lt;img src="https://communities.vmware.com/t5/image/serverpage/image-id/67942iA9BD5AE9F4207126/image-size/large?v=v2&amp;amp;px=999" role="button" title="pastedImage_3.png" alt="pastedImage_3.png" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Tue, 13 Sep 2016 12:34:51 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923859#M27077</guid>
      <dc:creator>Mike_Yazbeck</dc:creator>
      <dc:date>2016-09-13T12:34:51Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923860#M27078</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;@Mike_Yazbeck&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;I just see the result on the picture you posted but not the script you generated it with &lt;img id="smileyhappy" class="emoticon emoticon-smileyhappy" src="https://communities.vmware.com/i/smilies/16x16_smiley-happy.png" alt="Smiley Happy" title="Smiley Happy" /&gt; Could you please post it here?&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Thanks in advance!&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Wed, 30 Nov 2016 12:39:16 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923860#M27078</guid>
      <dc:creator>WhiteCase</dc:creator>
      <dc:date>2016-11-30T12:39:16Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923861#M27079</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Did you see my post from a couple days ago?&amp;nbsp; Hopefully this is what you've been looking for.&amp;nbsp; &lt;A href="https://communities.vmware.com/thread/548671"&gt;How to trace a VM disk to a guest disk.&lt;/A&gt;&lt;/P&gt;&lt;P&gt;&lt;SPAN style="font-size: 10pt;"&gt;&lt;BR /&gt;&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;&lt;SPAN style="font-size: 10pt;"&gt;It describes a method to perform this trace that is more reliable than referencing scsibus and scsitargetid.&amp;nbsp; The method s&lt;/SPAN&gt;hould work irrespective of guest OS.&amp;nbsp; PowerShell code for Windows included.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Briefly:&amp;nbsp; for disks that are not physical mode RDM, match VMware disk uuid to serial number of disk in guest.&amp;nbsp; For physical mode RDM disks, match ScsiCanonicalName to serial number of disk in guest (perhaps with some ASCII to HEX conversion as required in my environment built on NetApp).&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Not saying this is foolproof but if you find a place where this doesn't work I'd like to hear about it.&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Thu, 15 Dec 2016 18:40:53 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923861#M27079</guid>
      <dc:creator>FMON</dc:creator>
      <dc:date>2016-12-15T18:40:53Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923862#M27080</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;&lt;B&gt;LucD&lt;/B&gt; &lt;/P&gt;&lt;P&gt;What about combining the PowerShell from this website: &lt;A href="https://4sysops.com/archives/map-vmware-virtual-disks-and-windows-drive-volumes-with-a-powershell-script/" title="https://4sysops.com/archives/map-vmware-virtual-disks-and-windows-drive-volumes-with-a-powershell-script/"&gt;https://4sysops.com/archives/map-vmware-virtual-disks-and-windows-drive-volumes-with-a-powershell-script/&lt;/A&gt; &lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Tue, 28 Mar 2017 03:18:09 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923862#M27080</guid>
      <dc:creator>AlbertWT</dc:creator>
      <dc:date>2017-03-28T03:18:09Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923863#M27081</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;I have seen that method before, but found out that it doesn't work when the controllers and disks have been manipulated after the creation of the VM.&lt;/P&gt;&lt;P&gt;The IDs assigned to the controllers do not seem to follow a logic (that I know of).&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Tue, 28 Mar 2017 05:10:56 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923863#M27081</guid>
      <dc:creator>LucD</dc:creator>
      <dc:date>2017-03-28T05:10:56Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923864#M27082</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;&lt;B&gt;FMON&lt;/B&gt;​ I went to test your SerialNumber method and found that the WMI value is empty on all the VMs that I tested on, and they are not RDMs.&amp;nbsp; Any thoughts?&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;BLOCKQUOTE&gt;&lt;P&gt;ConfigManagerErrorCode&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 0&lt;/P&gt;&lt;P&gt;LastErrorCode&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;NeedsCleaning&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;Status&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : OK&lt;/P&gt;&lt;P&gt;DeviceID&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : \\.\PHYSICALDRIVE1&lt;/P&gt;&lt;P&gt;StatusInfo&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;Partitions&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 1&lt;/P&gt;&lt;P&gt;BytesPerSector&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 512&lt;/P&gt;&lt;P&gt;ConfigManagerUserConfig&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : False&lt;/P&gt;&lt;P&gt;DefaultBlockSize&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;Index&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 1&lt;/P&gt;&lt;P&gt;InstallDate&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;InterfaceType&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : SCSI&lt;/P&gt;&lt;P&gt;MaxBlockSize&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;MaxMediaSize&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;MinBlockSize&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;NumberOfMediaSupported&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;SectorsPerTrack&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 63&lt;/P&gt;&lt;P&gt;Size&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 53686402560&lt;/P&gt;&lt;P&gt;TotalCylinders&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 6527&lt;/P&gt;&lt;P&gt;TotalHeads&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 255&lt;/P&gt;&lt;P&gt;TotalSectors&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 104856255&lt;/P&gt;&lt;P&gt;TotalTracks&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 1664385&lt;/P&gt;&lt;P&gt;TracksPerCylinder&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 255&lt;/P&gt;&lt;P&gt;__GENUS&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 2&lt;/P&gt;&lt;P&gt;__CLASS&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : Win32_DiskDrive&lt;/P&gt;&lt;P&gt;__SUPERCLASS&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : CIM_DiskDrive&lt;/P&gt;&lt;P&gt;__DYNASTY&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : CIM_ManagedSystemElement&lt;/P&gt;&lt;P&gt;__RELPATH&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : Win32_DiskDrive.DeviceID="\\\\.\\PHYSICALDRIVE1"&lt;/P&gt;&lt;P&gt;__PROPERTY_COUNT&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 51&lt;/P&gt;&lt;P&gt;__DERIVATION&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : {CIM_DiskDrive, CIM_MediaAccessDevice, CIM_LogicalDevice, CIM_LogicalElement...}&lt;/P&gt;&lt;P&gt;__SERVER&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : Server21&lt;/P&gt;&lt;P&gt;__NAMESPACE&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : root\cimv2&lt;/P&gt;&lt;P&gt;__PATH&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : \\Server21\root\cimv2:Win32_DiskDrive.DeviceID="\\\\.\\PHYSICALDRIVE1"&lt;/P&gt;&lt;P&gt;Availability&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;Capabilities&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : {3, 4}&lt;/P&gt;&lt;P&gt;CapabilityDescriptions&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : {Random Access, Supports Writing}&lt;/P&gt;&lt;P&gt;Caption&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : VMware Virtual disk SCSI Disk Device&lt;/P&gt;&lt;P&gt;CompressionMethod&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;CreationClassName&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : Win32_DiskDrive&lt;/P&gt;&lt;P&gt;Description&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : Disk drive&lt;/P&gt;&lt;P&gt;ErrorCleared&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;ErrorDescription&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;ErrorMethodology&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;FirmwareRevision&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 1.0&lt;/P&gt;&lt;P&gt;Manufacturer&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : (Standard disk drives)&lt;/P&gt;&lt;P&gt;MediaLoaded&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : True&lt;/P&gt;&lt;P&gt;MediaType&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : Fixed hard disk media&lt;/P&gt;&lt;P&gt;Model&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : VMware Virtual disk SCSI Disk Device&lt;/P&gt;&lt;P&gt;Name&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : \\.\PHYSICALDRIVE1&lt;/P&gt;&lt;P&gt;PNPDeviceID&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : SCSI\DISK&amp;amp;VEN_VMWARE&amp;amp;PROD_VIRTUAL_DISK\4&amp;amp;3B5019BE&amp;amp;0&amp;amp;000100&lt;/P&gt;&lt;P&gt;PowerManagementCapabilities :&lt;/P&gt;&lt;P&gt;PowerManagementSupported&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;SCSIBus&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 0&lt;/P&gt;&lt;P&gt;SCSILogicalUnit&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 0&lt;/P&gt;&lt;P&gt;SCSIPort&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 2&lt;/P&gt;&lt;P&gt;SCSITargetId&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : 1&lt;/P&gt;&lt;P&gt;SerialNumber&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;Signature&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;SystemCreationClassName&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : Win32_ComputerSystem&lt;/P&gt;&lt;P&gt;SystemName&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : Server21&lt;/P&gt;&lt;P&gt;Scope&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : System.Management.ManagementScope&lt;/P&gt;&lt;P&gt;Path&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : \\Server21\root\cimv2:Win32_DiskDrive.DeviceID="\\\\.\\PHYSICALDRIVE1"&lt;/P&gt;&lt;P&gt;Options&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : System.Management.ObjectGetOptions&lt;/P&gt;&lt;P&gt;ClassPath&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : \\Server21\root\cimv2:Win32_DiskDrive&lt;/P&gt;&lt;P&gt;Properties&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : {Availability, BytesPerSector, Capabilities, CapabilityDescriptions...}&lt;/P&gt;&lt;P&gt;SystemProperties&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : {__GENUS, __CLASS, __SUPERCLASS, __DYNASTY...}&lt;/P&gt;&lt;P&gt;Qualifiers&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; : {dynamic, Locale, provider, UUID}&lt;/P&gt;&lt;P&gt;Site&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;P&gt;Container&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; :&lt;/P&gt;&lt;/BLOCKQUOTE&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Thu, 12 Oct 2017 22:00:50 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923864#M27082</guid>
      <dc:creator>jamesl73</dc:creator>
      <dc:date>2017-10-12T22:00:50Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923865#M27083</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Yes, I guess you are right in this case &lt;B&gt;LucD&lt;/B&gt;​ I have never seen any working script that is consistently showing the correct result.&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Thu, 12 Oct 2017 22:04:40 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923865#M27083</guid>
      <dc:creator>AlbertWT</dc:creator>
      <dc:date>2017-10-12T22:04:40Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923866#M27084</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;&lt;B&gt;FMON&lt;/B&gt;​&amp;nbsp; Update:&amp;nbsp; It looks like the serial number is just missing from Windows Server 2016.&amp;nbsp; It shows up on our 2008 and 2012 servers.&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Thu, 12 Oct 2017 22:59:19 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923866#M27084</guid>
      <dc:creator>jamesl73</dc:creator>
      <dc:date>2017-10-12T22:59:19Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923867#M27085</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;sorry Mike.. some time has passed but...you said you ran the script &lt;STRONG&gt;against&lt;/STRONG&gt; those servers, but I guess from what I see you run the script from &lt;STRONG&gt;within&lt;/STRONG&gt; the OS right? So you need Windows admin credentials. I'm a VMware admin but not OS admin.. Arnim Van Lieshout already considered this a while ago but his script worked only for vSCSI 0. &lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Fri, 20 Oct 2017 11:12:08 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923867#M27085</guid>
      <dc:creator>GabCava</dc:creator>
      <dc:date>2017-10-20T11:12:08Z</dc:date>
    </item>
    <item>
      <title>Re: Matching VM Disks to Windows Disk for SCSI Controller 1 (scripts online always work for controller 0)</title>
      <link>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923868#M27086</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;I found that for some reason our automation for Windows Server 2016 was somehow missing a setting in the .vmx file.&amp;nbsp; After updating the .vmx with the below parameter we are able to get the serial number from WMI.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;&lt;SPAN style="font-size: 10.0pt; font-family: 'Segoe UI',sans-serif; color: black;"&gt;disk.EnableUUID = "TRUE"&lt;/SPAN&gt;&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Thu, 16 Nov 2017 20:54:16 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-PowerCLI-Discussions/Matching-VM-Disks-to-Windows-Disk-for-SCSI-Controller-1-scripts/m-p/923868#M27086</guid>
      <dc:creator>jamesl73</dc:creator>
      <dc:date>2017-11-16T20:54:16Z</dc:date>
    </item>
  </channel>