    <title>topic Re: ESXI v7.0.3 - 440ar Raid - high disk latency in Storage Performance</title>
    <link>https://communities.vmware.com/t5/Storage-Performance/ESXI-v7-0-3-440ar-Raid-high-disk-latency/m-p/2993272#M5597</link>
    <description>&lt;P&gt;I deaktivated now the SSD Smart Path in the HP Settings.&lt;BR /&gt;Now the latency is much better.&lt;BR /&gt;I dont think that any hardware was or is damaged because i tried to change same parts.&lt;BR /&gt;&lt;BR /&gt;But i dont know why it suddenly happens.&lt;BR /&gt;&lt;BR /&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
    <pubDate>Mon, 30 Oct 2023 06:15:30 GMT</pubDate>
    <dc:creator>PLP-Lackner</dc:creator>
    <dc:date>2023-10-30T06:15:30Z</dc:date>
    <item>
      <title>ESXI v7.0.3 - 440ar Raid - high disk latency</title>
      <link>https://communities.vmware.com/t5/Storage-Performance/ESXI-v7-0-3-440ar-Raid-high-disk-latency/m-p/2989336#M5574</link>
      <description>&lt;P&gt;I have an&amp;nbsp;&lt;SPAN&gt;ProLiant DL360 Gen9 with a 440ar Raid Controller with Raid 6 and 4 SSD Disks.&lt;BR /&gt;Suddenly i have very high disk latency even if there is no vm running.&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;I have already tryed to change the controller and the&amp;nbsp;Smart Storage Battery but it still does not work.&lt;BR /&gt;I have also the latest driver updates.&lt;BR /&gt;&lt;BR /&gt;&lt;/P&gt;&lt;P&gt;VMware ESXi 7.0.3 build-20036589&lt;BR /&gt;VMware ESXi 7.0 Update 3&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;BR /&gt;Smart Array P440ar in Slot 0 (Embedded)&lt;BR /&gt;Bus Interface: PCI&lt;BR /&gt;Slot: 0&lt;BR /&gt;Serial Number: PDNLH0BRH753PJ&lt;BR /&gt;Cache Serial Number: PDNLH0BRH753PJ&lt;BR /&gt;RAID 6 Status: Enabled&lt;BR /&gt;Controller Status: OK&lt;BR /&gt;Hardware Revision: B&lt;BR /&gt;Firmware Version: 7.00&lt;BR /&gt;Firmware Supports Online Firmware Activation: False&lt;BR /&gt;Rebuild Priority: High&lt;BR /&gt;Expand Priority: Medium&lt;BR /&gt;Surface Scan Delay: 3 secs&lt;BR /&gt;Surface Scan Mode: Idle&lt;BR /&gt;Parallel Surface Scan Supported: Yes&lt;BR /&gt;Current Parallel Surface Scan Count: 1&lt;BR /&gt;Max Parallel Surface Scan Count: 16&lt;BR /&gt;Queue Depth: Automatic&lt;BR /&gt;Monitor and Performance Delay: 60 min&lt;BR /&gt;Elevator Sort: Enabled&lt;BR /&gt;Degraded Performance Optimization: Disabled&lt;BR /&gt;Inconsistency Repair Policy: Disabled&lt;BR /&gt;Wait for Cache Room: Disabled&lt;BR /&gt;Surface Analysis Inconsistency Notification: Disabled&lt;BR /&gt;Post Prompt Timeout: 15 secs&lt;BR /&gt;Cache Board Present: True&lt;BR /&gt;Cache Status: Not Configured&lt;BR /&gt;Drive Write Cache: Disabled&lt;BR /&gt;Total Cache Size: 2.0&lt;BR /&gt;Total Cache Memory Available: 1.8&lt;BR /&gt;Battery Backed Cache Size: 1.8&lt;BR /&gt;No-Battery Write Cache: Disabled&lt;BR /&gt;SSD Caching RAID5 WriteBack Enabled: True&lt;BR /&gt;SSD Caching Version: 2&lt;BR /&gt;Cache Backup Power Source: Batteries&lt;BR /&gt;Battery/Capacitor Count: 1&lt;BR /&gt;Battery/Capacitor Status: OK&lt;BR /&gt;SATA NCQ Supported: True&lt;BR /&gt;Spare Activation Mode: Activate on physical drive failure (default)&lt;BR /&gt;Controller Temperature (C): 49&lt;BR /&gt;Cache Module Temperature (C): 43&lt;BR /&gt;Number of Ports: 2 Internal only&lt;BR /&gt;Encryption: Not Set&lt;BR /&gt;Express Local Encryption: False&lt;BR /&gt;Driver Name: nhpsa&lt;BR /&gt;Driver Version: 70.0051.0.100-4vmw&lt;BR /&gt;PCI Address (Domain&lt;img class="lia-deferred-image lia-image-emoji" src="https://communities.vmware.com/html/@EF38FDF84EE88E8CFA2B9746376E0E54/emoticons/1f68c.png" alt=":bus:" title=":bus:" /&gt;Device.Function): 0000:03:00.0&lt;BR /&gt;Negotiated PCIe Data Rate: PCIe 3.0 x8 (7880 MB/s)&lt;BR /&gt;Controller Mode: RAID&lt;BR /&gt;Pending Controller Mode: RAID&lt;BR /&gt;Port Max Phy Rate Limiting Supported: False&lt;BR /&gt;Latency Scheduler Setting: Disabled&lt;BR /&gt;Current Power Mode: MaxPerformance&lt;BR /&gt;Survival Mode: Enabled&lt;BR /&gt;Host Serial Number: CZJ6410R6R&lt;BR /&gt;Sanitize Erase Supported: True&lt;BR /&gt;Primary Boot Volume: None&lt;BR /&gt;Secondary Boot Volume: None&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Smart Array P440ar in Slot 0 (Embedded)&lt;/P&gt;&lt;P&gt;Array A&lt;/P&gt;&lt;P&gt;physicaldrive 1I:1:1&lt;BR /&gt;Port: 1I&lt;BR /&gt;Box: 1&lt;BR /&gt;Bay: 1&lt;BR /&gt;Status: OK&lt;BR /&gt;Drive Type: Data Drive&lt;BR /&gt;Interface Type: Solid State SATA&lt;BR /&gt;Size: 4 TB&lt;BR /&gt;Drive exposed to OS: False&lt;BR /&gt;Logical/Physical Block Size: 512/512&lt;BR /&gt;Firmware Revision: SVQ02B6Q&lt;BR /&gt;Serial Number: S5STNF0TB04130E&lt;BR /&gt;WWID: 31402EC001E1BE70&lt;BR /&gt;Model: ATA Samsung SSD 870&lt;BR /&gt;SATA NCQ Capable: True&lt;BR /&gt;SATA NCQ Enabled: True&lt;BR /&gt;Current Temperature (C): 34&lt;BR /&gt;Maximum Temperature (C): 46&lt;BR /&gt;SSD Smart Trip Wearout: Not Supported&lt;BR /&gt;PHY Count: 1&lt;BR /&gt;PHY Transfer Rate: 6.0Gbps&lt;BR /&gt;PHY Physical Link Rate: Unknown&lt;BR /&gt;PHY Maximum Link Rate: Unknown&lt;BR /&gt;Drive Authentication Status: OK&lt;BR /&gt;Carrier Application Version: 11&lt;BR /&gt;Carrier Bootloader Version: 6&lt;BR /&gt;Sanitize Erase Supported: False&lt;BR /&gt;Shingled Magnetic Recording Support: None&lt;/P&gt;&lt;P&gt;physicaldrive 1I:1:2&lt;BR /&gt;Port: 1I&lt;BR /&gt;Box: 1&lt;BR /&gt;Bay: 2&lt;BR /&gt;Status: OK&lt;BR /&gt;Drive Type: Data Drive&lt;BR /&gt;Interface Type: Solid State SATA&lt;BR /&gt;Size: 4 TB&lt;BR /&gt;Drive exposed to OS: False&lt;BR /&gt;Logical/Physical Block Size: 512/512&lt;BR /&gt;Firmware Revision: SVQ02B6Q&lt;BR /&gt;Serial Number: S5STNF0TB04132T&lt;BR /&gt;WWID: 31402EC001E1BE71&lt;BR /&gt;Model: ATA Samsung SSD 870&lt;BR /&gt;SATA NCQ Capable: True&lt;BR /&gt;SATA NCQ Enabled: True&lt;BR /&gt;Current Temperature (C): 36&lt;BR /&gt;Maximum Temperature (C): 47&lt;BR /&gt;SSD Smart Trip Wearout: Not Supported&lt;BR /&gt;PHY Count: 1&lt;BR /&gt;PHY Transfer Rate: 6.0Gbps&lt;BR /&gt;PHY Physical Link Rate: Unknown&lt;BR /&gt;PHY Maximum Link Rate: Unknown&lt;BR /&gt;Drive Authentication Status: OK&lt;BR /&gt;Carrier Application Version: 11&lt;BR /&gt;Carrier Bootloader Version: 6&lt;BR /&gt;Sanitize Erase Supported: False&lt;BR /&gt;Shingled Magnetic Recording Support: None&lt;/P&gt;&lt;P&gt;physicaldrive 1I:1:3&lt;BR /&gt;Port: 1I&lt;BR /&gt;Box: 1&lt;BR /&gt;Bay: 3&lt;BR /&gt;Status: OK&lt;BR /&gt;Drive Type: Data Drive&lt;BR /&gt;Interface Type: Solid State SATA&lt;BR /&gt;Size: 4 TB&lt;BR /&gt;Drive exposed to OS: False&lt;BR /&gt;Logical/Physical Block Size: 512/512&lt;BR /&gt;Firmware Revision: SVQ02B6Q&lt;BR /&gt;Serial Number: S5STNF0TB04152F&lt;BR /&gt;WWID: 31402EC001E1BE72&lt;BR /&gt;Model: ATA Samsung SSD 870&lt;BR /&gt;SATA NCQ Capable: True&lt;BR /&gt;SATA NCQ Enabled: True&lt;BR /&gt;Current Temperature (C): 32&lt;BR /&gt;Maximum Temperature (C): 44&lt;BR /&gt;SSD Smart Trip Wearout: Not Supported&lt;BR /&gt;PHY Count: 1&lt;BR /&gt;PHY Transfer Rate: 6.0Gbps&lt;BR /&gt;PHY Physical Link Rate: Unknown&lt;BR /&gt;PHY Maximum Link Rate: Unknown&lt;BR /&gt;Drive Authentication Status: OK&lt;BR /&gt;Carrier Application Version: 11&lt;BR /&gt;Carrier Bootloader Version: 6&lt;BR /&gt;Sanitize Erase Supported: False&lt;BR /&gt;Shingled Magnetic Recording Support: None&lt;/P&gt;&lt;P&gt;physicaldrive 1I:1:4&lt;BR /&gt;Port: 1I&lt;BR /&gt;Box: 1&lt;BR /&gt;Bay: 4&lt;BR /&gt;Status: OK&lt;BR /&gt;Drive Type: Data Drive&lt;BR /&gt;Interface Type: Solid State SATA&lt;BR /&gt;Size: 4 TB&lt;BR /&gt;Drive exposed to OS: False&lt;BR /&gt;Logical/Physical Block Size: 512/512&lt;BR /&gt;Firmware Revision: SVQ02B6Q&lt;BR /&gt;Serial Number: S5STNF0TB04149L&lt;BR /&gt;WWID: 31402EC001E1BE73&lt;BR /&gt;Model: ATA Samsung SSD 870&lt;BR /&gt;SATA NCQ Capable: True&lt;BR /&gt;SATA NCQ Enabled: True&lt;BR /&gt;Current Temperature (C): 29&lt;BR /&gt;Maximum Temperature (C): 45&lt;BR /&gt;SSD Smart Trip Wearout: Not Supported&lt;BR /&gt;PHY Count: 1&lt;BR /&gt;PHY Transfer Rate: 6.0Gbps&lt;BR /&gt;PHY Physical Link Rate: Unknown&lt;BR /&gt;PHY Maximum Link Rate: Unknown&lt;BR /&gt;Drive Authentication Status: OK&lt;BR /&gt;Carrier Application Version: 11&lt;BR /&gt;Carrier Bootloader Version: 6&lt;BR /&gt;Sanitize Erase Supported: False&lt;BR /&gt;Shingled Magnetic Recording Support: None&lt;/P&gt;</description>
      <pubDate>Mon, 02 Oct 2023 17:16:43 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/Storage-Performance/ESXI-v7-0-3-440ar-Raid-high-disk-latency/m-p/2989336#M5574</guid>
      <dc:creator>PLP-Lackner</dc:creator>
      <dc:date>2023-10-02T17:16:43Z</dc:date>
    </item>
    <item>
      <title>Re: ESXI v7.0.3 - 440ar Raid - high disk latency</title>
      <link>https://communities.vmware.com/t5/Storage-Performance/ESXI-v7-0-3-440ar-Raid-high-disk-latency/m-p/2992613#M5596</link>
      <description>&lt;P&gt;At first glance, it looks like (maybe) a runaway process.&amp;nbsp;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Is this machine part of a host cluster or is it stand-alone?&amp;nbsp; Assuming no VM's are running, was this a new host added to a cluster and is DRS enabled?&amp;nbsp; I'm asking for context to see how the infrastructure is connected, or how this server plays into your set-up.&amp;nbsp; That would help track-down the best place to address the problem.&lt;/P&gt;</description>
      <pubDate>Wed, 25 Oct 2023 13:08:18 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/Storage-Performance/ESXI-v7-0-3-440ar-Raid-high-disk-latency/m-p/2992613#M5596</guid>
      <dc:creator>NateNateNAte</dc:creator>
      <dc:date>2023-10-25T13:08:18Z</dc:date>
    </item>
    <item>
      <title>Re: ESXI v7.0.3 - 440ar Raid - high disk latency</title>
      <link>https://communities.vmware.com/t5/Storage-Performance/ESXI-v7-0-3-440ar-Raid-high-disk-latency/m-p/2993272#M5597</link>
      <description>&lt;P&gt;I deaktivated now the SSD Smart Path in the HP Settings.&lt;BR /&gt;Now the latency is much better.&lt;BR /&gt;I dont think that any hardware was or is damaged because i tried to change same parts.&lt;BR /&gt;&lt;BR /&gt;But i dont know why it suddenly happens.&lt;BR /&gt;&lt;BR /&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 30 Oct 2023 06:15:30 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/Storage-Performance/ESXI-v7-0-3-440ar-Raid-high-disk-latency/m-p/2993272#M5597</guid>
      <dc:creator>PLP-Lackner</dc:creator>
      <dc:date>2023-10-30T06:15:30Z</dc:date>
    </item>
    <item>
      <title>Re: ESXI v7.0.3 - 440ar Raid - high disk latency</title>
      <link>https://communities.vmware.com/t5/Storage-Performance/ESXI-v7-0-3-440ar-Raid-high-disk-latency/m-p/2994538#M5598</link>
      <description>&lt;P&gt;Interesting that the smart-path setting helped to reduce that latency.&amp;nbsp; If it was that configuration even after you changed out HW/parts, then I would be looking at the firmware.&lt;/P&gt;&lt;P&gt;As to why it happened - that would definitely be a casefile to send to HP. It reminds me of some problems I used to have with HW that had an unknown software bug that allowed for a buffer overwrite to fill up an SQL server overnight.&amp;nbsp; We had to get the HW vendor involved to do a firmware update. It was not a common bug or occurrence, it just happened when we had a certain configuration applied.&amp;nbsp; We just did a pentest without realizing we were doing a pentest.&amp;nbsp;&amp;nbsp;&lt;/P&gt;&lt;P&gt;I'm glad you got some resolution though.&amp;nbsp; It's up to you if you want to open a case with HP. Or VMware for that matter (just to cover all bases)&lt;/P&gt;</description>
      <pubDate>Tue, 07 Nov 2023 15:04:17 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/Storage-Performance/ESXI-v7-0-3-440ar-Raid-high-disk-latency/m-p/2994538#M5598</guid>
      <dc:creator>NateNateNAte</dc:creator>
      <dc:date>2023-11-07T15:04:17Z</dc:date>