<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: change space efficiency (DD/C to C) fails in VMware vSAN Discussions</title>
    <link>https://communities.vmware.com/t5/VMware-vSAN-Discussions/change-space-efficiency-DD-C-to-C-fails/m-p/2990631#M15687</link>
    <description>&lt;P&gt;&lt;a href="https://communities.vmware.com/t5/user/viewprofilepage/user-id/5576901"&gt;@efpbe&lt;/a&gt;, Are you sure that is the 'vSAN Default Storage Policy' applied to that object?(I think it is possible to still have multiple of these in SPBM inventory)&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Asking as that object does not have 'No preference' rule on it - you should change it to 'No preference', apply it to all objects and validate this (from 'esxli vsan debug object list --all' output) has been applied to everything (not just what is registered in inventory!) that has 'Dedup&amp;amp;Compression' rule, then you should be able to reformat to Compression only (and change policy to that also, but not mandatory).&lt;/P&gt;</description>
    <pubDate>Wed, 11 Oct 2023 19:17:38 GMT</pubDate>
    <dc:creator>TheBobkin</dc:creator>
    <dc:date>2023-10-11T19:17:38Z</dc:date>
    <item>
      <title>change space efficiency (DD/C to C) fails</title>
      <link>https://communities.vmware.com/t5/VMware-vSAN-Discussions/change-space-efficiency-DD-C-to-C-fails/m-p/2990080#M15677</link>
      <description>&lt;P&gt;Hi everyone&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;On one of our environments, we have to go back to compression only due to performance recommendations :&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="efpbe_1-1696669200621.png" style="width: 400px;"&gt;&lt;img src="https://communities.vmware.com/t5/image/serverpage/image-id/103875i3CD64D5249B98E0E/image-size/medium/is-moderation-mode/true?v=v2&amp;amp;px=400" role="button" title="efpbe_1-1696669200621.png" alt="efpbe_1-1696669200621.png" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;We checked if everything was correct in terms of space, policies and health of each of the esxi but for some unknown reason, the conversion fails at 10% : &lt;EM&gt;General vSAN error. Resource check failed - Internal failure happened during the resource check. Please check clomd.log&lt;/EM&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;On the host in question, we've checked the clomd.log (in attachments) and the only error I see is the multiple values like this :&amp;nbsp;&lt;EM&gt;CLOMDecom_ComponentNeedsEvac: Could not find disk 00000000-0000-0000-0000-000000000000&lt;/EM&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;But i'm not sure is this is the problem relative to the situation.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Any help is appreciated.&lt;/P&gt;</description>
      <pubDate>Sat, 07 Oct 2023 09:07:03 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-vSAN-Discussions/change-space-efficiency-DD-C-to-C-fails/m-p/2990080#M15677</guid>
      <dc:creator>efpbe</dc:creator>
      <dc:date>2023-10-07T09:07:03Z</dc:date>
    </item>
    <item>
      <title>Re: change space efficiency (DD/C to C) fails</title>
      <link>https://communities.vmware.com/t5/VMware-vSAN-Discussions/change-space-efficiency-DD-C-to-C-fails/m-p/2990094#M15678</link>
      <description>&lt;P&gt;&lt;a href="https://communities.vmware.com/t5/user/viewprofilepage/user-id/5576901"&gt;@efpbe&lt;/a&gt;,&amp;nbsp;Can you please share the layout/policy of this object '5047d264-da13-bbf6-bb93-84160c080880'? Maybe it has a dedupe&amp;amp;compression-only policy:&lt;/P&gt;&lt;LI-CODE lang="markup"&gt;esxcli vsan debug object list -u 5047d264-da13-bbf6-bb93-84160c080880&lt;/LI-CODE&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;LI-CODE lang="markup"&gt;2023-10-07T08:26:57.657Z No(29) clomd[38181686]: [Originator@6876] CLOMWhatIfRecordResourceAndReplicas: targetPolicy: UFT1/LFT0, capacity-pref=0, currentPolicy: UFT1/LFT0, capacity-pref=0, item.origObjectAddressSpace=10700718080, targetAddress(totalComponentAddressSpace)=10700718080
2023-10-07T08:26:57.658Z No(29) clomd[38181686]: [Originator@6876] CLOM_CheckClusterResourcesForPolicy: Target datastore space efficiency policy is not compatible with current cluster configuration. DedupAndCompression:1, CompressionOnly:0, None:0
2023-10-07T08:26:57.658Z No(29) clomd[38181686]: [Originator@6876] CLOMWhatIfObjectDecom: Couldn't check cluster resources: Failure
2023-10-07T08:26:57.658Z No(29) clomd[38181686]: [Originator@6876] CLOMWhatIfRunDecom: Failed to decommission object 5047d264-da13-bbf6-bb93-84160c080880: Failure, doDeltaDecom = 0.&lt;/LI-CODE&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Sat, 07 Oct 2023 15:57:38 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-vSAN-Discussions/change-space-efficiency-DD-C-to-C-fails/m-p/2990094#M15678</guid>
      <dc:creator>TheBobkin</dc:creator>
      <dc:date>2023-10-07T15:57:38Z</dc:date>
    </item>
    <item>
      <title>Re: change space efficiency (DD/C to C) fails</title>
      <link>https://communities.vmware.com/t5/VMware-vSAN-Discussions/change-space-efficiency-DD-C-to-C-fails/m-p/2990331#M15681</link>
      <description>&lt;P&gt;Yes, you're right !&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="efpbe_0-1696897700424.png" style="width: 400px;"&gt;&lt;img src="https://communities.vmware.com/t5/image/serverpage/image-id/103898i8AC21DA33579862A/image-size/medium/is-moderation-mode/true?v=v2&amp;amp;px=400" role="button" title="efpbe_0-1696897700424.png" alt="efpbe_0-1696897700424.png" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;I think it's because the vSAN Default Storage Policy was in this status :&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="efpbe_1-1696897743747.png" style="width: 400px;"&gt;&lt;img src="https://communities.vmware.com/t5/image/serverpage/image-id/103899i74F093C4CE50D11F/image-size/medium/is-moderation-mode/true?v=v2&amp;amp;px=400" role="button" title="efpbe_1-1696897743747.png" alt="efpbe_1-1696897743747.png" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;but, when I put the cluster to "Compression only" and change the default policy to "Compression only" also, i've this error :&lt;/P&gt;&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="efpbe_2-1696897806313.png" style="width: 400px;"&gt;&lt;img src="https://communities.vmware.com/t5/image/serverpage/image-id/103900i53410BBD33EF7B95/image-size/medium/is-moderation-mode/true?v=v2&amp;amp;px=400" role="button" title="efpbe_2-1696897806313.png" alt="efpbe_2-1696897806313.png" /&gt;&lt;/span&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;I'm not&amp;nbsp;aware of wich best practices must I follow to migrate from deduplication&amp;amp;compression to compression only &lt;img class="lia-deferred-image lia-image-emoji" src="https://communities.vmware.com/html/@ECFD0D55972316700FC4170A6FAD6DD9/emoticons/1f615.png" alt=":confused_face:" title=":confused_face:" /&gt;&lt;/P&gt;</description>
      <pubDate>Tue, 10 Oct 2023 00:37:02 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-vSAN-Discussions/change-space-efficiency-DD-C-to-C-fails/m-p/2990331#M15681</guid>
      <dc:creator>efpbe</dc:creator>
      <dc:date>2023-10-10T00:37:02Z</dc:date>
    </item>
    <item>
      <title>Re: change space efficiency (DD/C to C) fails</title>
      <link>https://communities.vmware.com/t5/VMware-vSAN-Discussions/change-space-efficiency-DD-C-to-C-fails/m-p/2990631#M15687</link>
      <description>&lt;P&gt;&lt;a href="https://communities.vmware.com/t5/user/viewprofilepage/user-id/5576901"&gt;@efpbe&lt;/a&gt;, Are you sure that is the 'vSAN Default Storage Policy' applied to that object?(I think it is possible to still have multiple of these in SPBM inventory)&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Asking as that object does not have 'No preference' rule on it - you should change it to 'No preference', apply it to all objects and validate this (from 'esxli vsan debug object list --all' output) has been applied to everything (not just what is registered in inventory!) that has 'Dedup&amp;amp;Compression' rule, then you should be able to reformat to Compression only (and change policy to that also, but not mandatory).&lt;/P&gt;</description>
      <pubDate>Wed, 11 Oct 2023 19:17:38 GMT</pubDate>
      <guid>https://communities.vmware.com/t5/VMware-vSAN-Discussions/change-space-efficiency-DD-C-to-C-fails/m-p/2990631#M15687</guid>
      <dc:creator>TheBobkin</dc:creator>
      <dc:date>2023-10-11T19:17:38Z</dc:date>
    </item>
  </channel>
</rss>
