I was having trouble deploying NSX-T 3.0 in VCF 4.0
I wanted to do the cleanup to leave clean because I had some weird errors. I deconfigured the esxi's, I removed the node and uplink transport profile.
I recreated the uplink profile in MTU900.
But when I recreate the transport node profile using the VDS dvswitch. I have the following error
Unsupported field MTU specified in uplink profile [BaseHostSwitchProfile/271e67fa-2036-4bb8-b5e7-74126e1fdb94] for VDS . Please update MTU from vSphere. (Error code: 9531)
I don't understand because my dvswitch is well configured in MTU 9000.
If you are using vDS 7.0 you do not configure the MTU in NSX-T, as this is already defined in vCenter. That field in the uplink profile only applies to N-VDS.
Just leave it blank.
If you are using vDS 7.0 you do not configure the MTU in NSX-T, as this is already defined in vCenter. That field in the uplink profile only applies to N-VDS.
Just leave it blank.
Great, thanks.
So I was able to reconfigure the NSX on the nodes. However, it still makes me a mistake on edge deployment via SDDC.
Failed to fetch default overlay tranposrt zone from nsxt manager {0}.
Error
Message: Failed to fetch default overlay tranposrt zone from nsxt manager {0}.
Remediation Message:
Reference Token: FIV7EK
Cause:
Type: java.lang.IllegalArgumentException
Message: No default overlay TZ found for nsxt manager:
While I have the default overlay zone.