vmware not detecting storage on hpe proliant dl360 gen10
Please read the first article in my signature and try again.
Welcome to the Community,
without any details, one can just guess. Maybe it's too dark in the server room, so that the server cannot see its disks ;-))
Make sure that the RAID (logical volumes) is configured, and use the HPE customized ESXi installation image, which contains required drivers.
André
Hi,
You should provide a few more details:
You can post some photos of the error message.
ARomeo
. HPE Smart Array S100i SR Gen10 controller works only in UEFI Bios Mode. Please recheck on system bios ion boot options, if you are on UEFI mode. Also make sure the Embedded controller is enabled in BIOS
ARomeo
From the image you posted I would say that everything is ok!
What's wrong with you?
Did you apply the change and reboot?
Accessing the Smart Storage Administrator and Configuring Drives - YouTube
Raid Server HPE ProLiant DL380 Gen 10 - YouTube
ARomeo
The S100i is a Software RAID controller, which is not supported on ESXi.
ESXi only supports Hardware RAID controllers, like the "P" models
André