SRM 8.2 Failover test error after migration to virtual appliance

I have a client that recently had their vSphere environment upgraded to 6.7 u3 with external Platform Services controllers.

I just completed an upgrade/migration from Windows based SRM 6.5.1 to appliance based 8.2.

Everything looks good, however, when I run a failover test I get a customization error on the external PSC VM.

The error code is 255.

I found a document that says the tmp folder is blocked from execution. The document is for basic VMs, NOT a PSC appliance.

It gives instructions for changing the VMware tools conf file to use a different temp dir.

I am unable to find the file in the areas the document outlines.

Has anybody had this issue?

Know where the file lives?

Different fix?

Thanks

Jim

0 Kudos
1 Solution

Accepted Solutions
Cuthbert01
Enthusiast
Enthusiast
Jump to solution

Found the issue.

Protection on old PSC was set to no IP customization.

Set that on new PSC and all is good.