Hi All
I have 3 servers, each server has 1 ssd & 3 hhd disk 1 TB each. How can i calculate usage size of cluster ? i was told by vmware 80% of (3*3 = 9 ) 9 TB and substract overhead , and overdead size is difficult to estimate
Any suggestions Please ?
Thanks
i found answer
Only magnetic disks (HD) will be used for capacity, and that is the total capacity you will have. Depending on the "failures to tolerate" you will select per VM there will be an x number of copies of your data. So if you add the above up you will have the "raw" capacity, depending on the chosen number of copies your net results will vary.
So my calculation will be
FT=1
9 TB raw
4.5 TB usable
80% should be target usage to avoid data cruching
3.6 TB is the final #
thanks @depping
esxi1979,
Also note that if you go to Cluster / Monitor / vSan / Capacity you will find a capacity calculator for your environment:
It will make an estimate for you depending on the storage policy you choose.
Lars