Issue in Configuring vCloud 9.5 with NSX-T2.3.

Hi friends,

I am trying to configure vCloud Director 9.5.3 with vSphere 6.5 and NSX-t 2.3. The bellow error appear after providing NSX-T2.3 details.

Please help me if you have any solutions.

[ 899ee1b3-734e-4409-bf78-e682710b0b41 ] Failed to connect to the NSX Manager

- /api/2.0/services/vcconfig, error code 98

Regards,

Kishor Kulkarni

1 Solution

Accepted Solutions
kkulkarni
Contributor
Contributor
Jump to solution

Thanks Yezdi for your attention and solution. After doing all R&D, I installed VCD 9.7 and there I got option to connect NSX-T. I think VCD 9.5 supports only NSX-v not NSX-T.

Please suggest if I missed.

View solution in original post

Reply
0 Kudos
5 Replies
Sreejesh_D
Virtuoso
Virtuoso
Jump to solution

Hi Kishor,

can you please confirm vCD cell can reach the NSX manager on 443(https)? If it doesnt connect then please troubleshoot the network connectivity between NSX and vCD.

1. ssh to vCD cell.

2. Run curl to test connectivity on https port.

root@testvcd[ ~ ]# curl -v telnet://<NSX manager IP>:443

* Rebuilt URL to: telnet://<NSX manager IP>:443/

*   Trying <NSX manager IP>...

* TCP_NODELAY set

* Connected to <NSX manager IP> (<NSX manager IP>) port 443 (#0)

-SD [vExpert 14-19,VCIX6-NV&DCV,RHCE]

https://pingforinfo.com

https://twitter.com/sreejeshd

Reply
0 Kudos
kkulkarni
Contributor
Contributor
Jump to solution

Thanks Yezdi for your attention and solution. After doing all R&D, I installed VCD 9.7 and there I got option to connect NSX-T. I think VCD 9.5 supports only NSX-v not NSX-T.

Please suggest if I missed.

Reply
0 Kudos
Sreejesh_D
Virtuoso
Virtuoso
Jump to solution

Reply
0 Kudos
kkulkarni
Contributor
Contributor
Jump to solution

I tried to connect VCD9.5 to NSX-T by looking at the document you provided. But unluckily unable to configure and not found the steps to configure NSX-T in 9.5. But sin VCD9.7 they provided option to configure NSX-v or NSX-t. So its easy to understand and configure.

vSmartAssurance
Contributor
Contributor
Jump to solution

I am also facing the same issue.

I have brought up one VCD with 9.5 GA build, When I try to attach it with NSX-T 2.3.1.

I am getting below error, In interop matrix its mentioned as these versions are supported.

---> Failed to connect to the NSX-Manager -/api/2.0/services/vcconfig, error code 98

But reachability wise both VCD and NSX-T are reachable to each other.

Need help in resolving the same.

Reply
0 Kudos