11 Replies Latest reply on Jan 29, 2019 8:18 PM by Nancy111

    Renaming vSan vDS uplinks kills cluster

    erives Novice

      I am sure this is a vDS rookie mistake on my side but Renaming the vSan vDS uplinks on a vSan cluster will Kill the cluster, dead , the fact that my vcenter was within the cluster made things a little harder when trying to recover. I tried searching for documentation prior to making the change and there is no KB article explaining this behavior (GSS could not find one either.), but what it is more troubling is that no warning message is shown saying that the uplinks are being used and that stuff will stop working. Solution was to manually create a vSS and move and uplink and vmk to it, not fun since vC was down.