VMware Horizon Community
jmatz135
Hot Shot
Hot Shot

Windows 10 USB Redirection Fails to work on login

We have Windows 10 and Windows 7 Desktops all running Horizon View Agent 7.4.0.  These are all instant clone desktops.  On first login the Windows 10 desktops usb redirection fails with the error USB redirection is not available for this desktop

If you then disconnect and reconnect after like 30 seconds of USB initializing (which is a long time compared to Windows 7) the USB devices will show up properly.

On  our Windows 7 desktops the USB redirection works properly every time and is much faster to initialize.

21 Replies
RS82
Contributor
Contributor

We have the same issue with the Agent 7.4 in Windows 7 and Windows 10 Pools.

With the Agent 7.3.2 we don´t have problems.

Reply
0 Kudos
jmatz135
Hot Shot
Hot Shot

Great, so they reverted the change that was made in 7.3.1 in 7.4.0.  This is like the 3rd time VMware has done this with one of their products. 

Reply
0 Kudos
rabihmansour86
Enthusiast
Enthusiast

even on windows 8.1 we faced the same issue and its randomly

Reply
0 Kudos
Oneboss302
Enthusiast
Enthusiast

Having same issue. Tried 4.3.1 and no joy. Starting to make me crazy. Even the VMware engineers are having trouble.

Reply
0 Kudos
rabihmansour86
Enthusiast
Enthusiast

what do you mean by 4.3.1 ? Horizon version ?

Reply
0 Kudos
Oneboss302
Enthusiast
Enthusiast

Sorry. That was a typo. I meant 7.3.1

Reply
0 Kudos
agalliasistju
Enthusiast
Enthusiast

For clarity of the issue are you explaining, is this issue with the PCoIP protocol or the BLAST protocol, or both?

Reply
0 Kudos
Oneboss302
Enthusiast
Enthusiast

Same results using both BLAST or PCoIP

On my initial connection using  BLAST or PCoIP it shows USB Unavailable. If I disconnect from the desktop (not log off) and reconnect using  BLAST or PCoIP again, the USB becomes available.

If I log off from the desktop and reconnect using  BLAST or PCoIP it again is USB unavailable until I disconnect and reconnect

Reply
0 Kudos
jmatz135
Hot Shot
Hot Shot

I found this regedit helped with the issue in 7.3:

reg.exe add "HKLM\Software\VMware, Inc.\VMware VDM\Agent\USB" /t REG_DWORD /v UemTimeouts /d 120 /f

Reply
0 Kudos
Oneboss302
Enthusiast
Enthusiast

jmatz135

I am assuming you are adding this to the master golden image and recomposing or are you using a script to add it to the desktops themselves?

Reply
0 Kudos
jmatz135
Hot Shot
Hot Shot

I put this in the master golden image.

Reply
0 Kudos
Oneboss302
Enthusiast
Enthusiast

Going to try now without UEM and see if that is the issue first. then I will try the Regedit. Will update shortly. Takes me 20 minutes to fully recompose each time.  Thanks for the advice.

Reply
0 Kudos
agalliasistju
Enthusiast
Enthusiast

Alternatively, set the pool to neither refresh nor delete on logoff.  Then you can modify the existing test VM and reboot it without losing your changes.  This would save you the potential time "waste" of recomposing from a snapshotted template. 🙂

Reply
0 Kudos
Oneboss302
Enthusiast
Enthusiast

But I would not get the same machine each time, correct?

Reply
0 Kudos
agalliasistju
Enthusiast
Enthusiast

Correct.  That would only work if you modified every VM in the pool.  Typically for testing like this I create 1-3 VMs in a "test" pool.

Oneboss302
Enthusiast
Enthusiast

First test with removing UEM gave the same results so I can now exclude UEM as the culprit. I will now be trying using the registry edit.

Reply
0 Kudos
Oneboss302
Enthusiast
Enthusiast

OK, well it looked promising, but it now just waits for 2 minutes for the USB to become unavailable with the registry key added.

pastedImage_0.png

pastedImage_0.png

Reply
0 Kudos
jmatz135
Hot Shot
Hot Shot

Do you actually have the policy for the pool set to allow USB?  I only ever had the problem when trying to use USB and UEM smart policies to control USB.  Do you have any firewalls in place between your physical desktop and the VDI desktop?  USB traffic is on a different port 32111 than normal PCOIP or BLAST traffic.

Edit:  Also, are you connecting directly to connection servers or is there a device that you use like an F5 appliance in between?

Reply
0 Kudos
Oneboss302
Enthusiast
Enthusiast

I was thinking firewall, but that went out the window when I noticed it worked on reconnect.

No smart policy has been applied via UEM. I have tried it though,

Reply