VMware Cloud Community
GuyTC
Enthusiast
Enthusiast

P2V error code: 1223 & 112

A p2v i am doing on a Windows 2008 R2 server has failed on several attempts - always around the 15% - 20% mark. Same error codes reported : 1223 & 122 - anyone know what the errors are and how to fix them

Converter installed locally on the physical server.

Converter 6.1 used

Both file level and block level copy have been attempted

Log extracts:

2017-03-04T14:41:18.133+01:00 info vmware-converter-server[08164] [Originator@6876 sub=Default] [task,379] [task-6] -- ERROR -- Convert: converter.fault.CloneFault

--> (converter.fault.CloneFault) {

-->    faultCause = (vmodl.MethodFault) null,

-->    description = "File-level volume clone error failed with sourcevolume id \WindowsBitmapDriverVolumeId=[9B-36-6F-31-00-00-10-00-00-00-00-00] and target volume id ;)63?6130000010000000000. Error code: 1223",

-->    msg = ""

--> }

2017-03-04T23:17:16.120+01:00 info vmware-converter-server[04740] [Originator@6876 sub=Default] [task,338] [task-8] -- BEGIN -- Convert

2017-03-04T23:17:17.664+01:00 info vmware-converter-server[04740] [Originator@6876 sub=Default] [taskSpec,618] [task-8] [TaskMap] task-8:task-1

2017-03-04T23:17:17.664+01:00 info vmware-converter-server[02408] [Originator@6876 sub=ThreadPool] Thread enlisted

2017-03-04T23:37:01.339+01:00 error vmware-converter-server[02408] [Originator@6876 sub=Ufa.HTTPService] Failed to read request; stream: <io_obj p:0x0450974c, h:-1, <pipe '\\.\pipe\vmware-converter-server-soap'>, <pipe '\\.\pipe\vmware-converter-server-soap'>>, error: class Vmacore::TimeoutException(Operation timed out)

2017-03-04T23:37:21.369+01:00 error vmware-converter-server[03732] [Originator@6876 sub=Ufa.HTTPService] Failed to read request; stream: <io_obj p:0x045099ec, h:-1, <pipe '\\.\pipe\vmware-converter-server-soap'>, <pipe '\\.\pipe\vmware-converter-server-soap'>>, error: class Vmacore::TimeoutException(Operation timed out)

2017-03-04T23:48:24.853+01:00 error vmware-converter-server[04740] [Originator@6876 sub=Default] [task,350] [LRO] Unexpected Exception: converter.fault.CloneFault

2017-03-04T23:48:24.868+01:00 info vmware-converter-server[04740] [Originator@6876 sub=Default] [task,379] [task-8] -- ERROR -- Convert: converter.fault.CloneFault

--> (converter.fault.CloneFault) {

-->    faultCause = (vmodl.MethodFault) null,

-->    description = "File-level volume clone error failed with sourcevolume id \WindowsBitmapDriverVolumeId=[D1-EC-7A-BD-00-00-10-00-00-00-00-00] and target volume id 1-<.:7=+0000010000000000. Error code: 112",

-->    msg = ""

--> }

Anyone know what Error code: 1223 & Error code: 112 mean ? and how to fix them ?

Reply
0 Kudos
2 Replies
GaneshNetworks

Its explained here - https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=20185...

Error code, mentioned in the KB is different, but the issue is same.

~GaneshNetworks™~ If you found this or other information useful, please consider awarding points for "Correct" or "Helpful".
Reply
0 Kudos
GuyTC
Enthusiast
Enthusiast

Its not the same error message, code or the same version of Converter in the KB article you reference

Reply