Using update manager to update firmware

Is it possible to use update manager to update server firmware?  For example, can you update HP blade server firmware by connecting to an HP repository, or by adding systems insight manager to the equation?

Reply
0 Kudos
9 Replies
vmroyale
Immortal
Immortal

Only third party software would work with Update Manager, which would typically be packaged as a VIB. You'll have to use the HP tools to update the firmware.

Brian Atkinson | vExpert | VMTN Moderator | Author of "VCP5-DCV VMware Certified Professional-Data Center Virtualization on vSphere 5.5 Study Guide: VCP-550" | @vmroyale | http://vmroyale.com
peetz
Leadership
Leadership

You can apply HP firmware updates online through HP SUM, or through HP's vCenter Insight Control plugin.

See VMware Front Experience: Finally...: HP Online Firmware Updates for ESXi

and VMware Front Experience: HP releases Service Pack 2013.02.0 for ProLiant and updated software for ES...

- Andreas

Twitter: @VFrontDe, @ESXiPatches | https://esxi-patches.v-front.de | https://vibsdepot.v-front.de
TheVMinator
Expert
Expert

Which method is easier - SUM or vCenter Insight Control Plugin?  Do they require putting ESXi into maintenance mode?  Do they require rebooting ESXi?  Can it be automated?  Would update manager be involved at all in this or only HP's software?

Thanks!

Reply
0 Kudos
peetz
Leadership
Leadership

Update Manager is not involved at all. HP SUM is the easiest method, because it can be launched from the SPP DVD without any further requirements. The Insight Control plugin requires a vCenter server and an HP SIM installation.

Firmware updates are as disruptive as with other OS. They can be done online without entering maintenance mode, but some of them (e.g. server or Smartarray BIOS) will require a reboot to become effective (which is not forced).

Please note that NIC firmware updates are not available as online update components, and must still be applied by booting the ESXi host from the SPP DVD.

Twitter: @VFrontDe, @ESXiPatches | https://esxi-patches.v-front.de | https://vibsdepot.v-front.de
Reply
0 Kudos
TheVMinator
Expert
Expert

OK thanks for the info.  Part of the goal here is to not have to visit every ESXi host individuallly.  I am running vCenter Server, and SIM is an option.   Could I then do all of my online updates for 200 servers, except NIC firmware, from one central point of control?  I don't want to have to mount a DVD individually on every ESXi host...  thanks!

Reply
0 Kudos
peetz
Leadership
Leadership

Yes you can. But the Insight Control plugin requires licensing. And with HP SUM you can also update multiple hosts at once and remotely. You run HP SUM on a Windows or  Linux machine and connect to the hosts via network.

Twitter: @VFrontDe, @ESXiPatches | https://esxi-patches.v-front.de | https://vibsdepot.v-front.de
Reply
0 Kudos
TheVMinator
Expert
Expert

Thanks for the response.  If you can clarify will be helpful.  Am I correct in understanding then that:

  • There are two aspects involved in keeping the HP servers running ESXi up to date: 1.  Driver updates 2. Firmware updates

  • HP Driver updates for HP blades install within the hypervisor and are packaged as VIBs, therefore VMware update manager can be used to apply them online non-disruptively without requiring a reboot

  • HP Firmware updates are NOT provided as VIBs, and therefore updating them from a central point of administration involves using Insight Control Plugin for vCenter and may require a reboot

Is this correct?

Reply
0 Kudos
mediumrare
Enthusiast
Enthusiast

No.

Most (all?) of the driver updates require a reboot after installation, too.

Cheers

Reply
0 Kudos
peetz
Leadership
Leadership

All driver updates also require a reboot.

And there is a third component requiring updates and these are the HP Offline bundles (e.g. CIM providers for hardware monitoring). But these are also updated through Update Manager.

It is common practice to update all three components together. You will only need a single reboot then and minimize downtime. This method will also ensure maximum compatibility of firmware, drivers and tools.

HP does a pretty good job documenting the dependencies and compatbility. Refer to their recipes available here:

http://vibsdepot.hp.com/hpq/recipes/

- Andreas

Twitter: @VFrontDe, @ESXiPatches | https://esxi-patches.v-front.de | https://vibsdepot.v-front.de
Reply