Hi,
use the way that bards1888 posted. And i think you must use the megaraid2.xml file and pobably adidionaly add the pci subsystems id´s. http://communities.vmware.com/message/876485 and look for scrs28x for an example, hth, Reinhard. ps: Award points if you find answers helpful. Thanks. |
|
Thanks for the advice guys.
Wasn't 100% sure on how to run through all the procedures, but this is what I have tried. 1. Booted ESX server using the console option. 2. Executed lspci to find the device id for the controller. name: LSE LOGIC / SYMBIOLOGIC: UNKNOWN DEVICE 0413 (rev 02) 3. The vendor/device id is 1000:0413 4.The driver file being used is megaRAID_sas.xml, which I modifed an exisiting device with id 0411 to 0413. The reason why I chose megaRAID_sas.xml and not megaRAID2.xml is because this is the driver ESX uses during the first install. Is this correct, or do I have to add the whole sub-section in the .xml file in _sas.xml in ..raid2.xml? This is really annoying the hell out of me now.. Please help! http://SORRY GUYS, BUT HAVING RE-READ THE INSTRUCTIONS CAREFULLY I HAD FORGOT TO RUN ESXCFG-PCIID. IT WORKED! BUT NOW Vertual Centre is complaining when you try to add it as a host! THANKS GUYS. YOU WILL ALL BE GETTING POINTS! Newbie |
|
Hi, all.
I trying start ESX 3.5 on the Intel 865 chipset ( ICH5 ). After install I loading in "troubleshooting mode", customize gosata.sh and run it. --root@localhost root--# ./gosata.sh SATA BootFix for VMware ESX Server by Reinhard Partmann check ifrunning on an ESX host : isESX: 1 isESXfailsafe: 1 DEBUG: BOOT_MOUNTED 1 DEBUG: 1==BOOT_MOUNTED 1 INTeL ... VENDOR_FILENAME: ata_piix DEVICE_ID: 24d1 DEVICE_ID_REPLACE: 2920 creating temp directories... patching xml files... loading /etc/vmware/pci.xml... loading /etc/vmware/pciid/3c90x.xml... loading /etc/vmware/pciid/DAC960.xml... loading /etc/vmware/pciid/aacraid_esx30.xml... loading /etc/vmware/pciid/adp94xx.xml... loading /etc/vmware/pciid/ahci.xml... loading /etc/vmware/pciid/aic79xx.xml... loading /etc/vmware/pciid/aic7xxx.xml... loading /etc/vmware/pciid/ata_piix.xml... loading /etc/vmware/pciid/bnx2.xml... loading /etc/vmware/pciid/cciss.xml... loading /etc/vmware/pciid/e100.xml... loading /etc/vmware/pciid/e1000.xml... loading /etc/vmware/pciid/forcedeth.xml... loading /etc/vmware/pciid/igb.xml... loading /etc/vmware/pciid/ioat.xml... loading /etc/vmware/pciid/ips.xml... loading /etc/vmware/pciid/iscsi_mod.xml... loading /etc/vmware/pciid/lpfc_740.xml... loading /etc/vmware/pciid/megaraid2.xml... loading /etc/vmware/pciid/megaraid_sas.xml... loading /etc/vmware/pciid/mptscsi_2xx.xml... loading /etc/vmware/pciid/qla2300_707_vmw.xml... loading /etc/vmware/pciid/qla4010.xml... loading /etc/vmware/pciid/qla4022.xml... loading /etc/vmware/pciid/s2io.xml... loading /etc/vmware/pciid/sata_nv.xml... loading /etc/vmware/pciid/sata_promise.xml... loading /etc/vmware/pciid/sata_sil.xml... loading /etc/vmware/pciid/sata_svw.xml... loading /etc/vmware/pciid/sata_vsc.xml... loading /etc/vmware/pciid/tg3.xml... loading /etc/vmware/pciid/unm_nic.xml... writing /etc/vmware/pci.xml.merged Replacing /etc/vmware/pci.ids file... Replacing /etc/vmware/pcitable file... Replacing /etc/vmware/pcitable.Linux file... Replacing /etc/vmware/vmware-devices.map file... cleanup... 1 DONE. happy ESXing... But the server still does not run.
I run /bin/vm-support and collect log to usb flash.
/log/messages
Loading vmnixmod
Warning: loading /lib/vmware/vmnixmod.o will taint the kernel: non-GPL license - proprietary See http://www.tux.org/lkml/#export-tainted for information about tainted modules Module vmnixmod loaded, with warnings Loading VMkernel Using /lib/vmware/vmkernel 0: 0x0:0x0 1: .text 0x600000:0x226f90 2: .data 0x1403000:0x261e8 3: .rodata 0x826fa0:0x492d3 4: .bss 0x1429200:0x13f2840 5: .comment 0x0:0x1ea8 6: .shstrtab 0x0:0x3d 7: .symtab 0x0:0x29450 8: .strtab 0x0:0x32b0f The vmkernel is loaded. Loading vmklinux Using /lib/vmware/vmklinux Module load of vmklinux succeeded with --exportsym option. Loading configuration No driver found for 'Vend:Dvid' 'Subv:Subd' at Bus:Sl.F. Trying just id No vmkernel driver found for 'Vend:Dvid' 'Subv:Subd' at Bus:Sl.F. No driver found for 'bus' '' at Spawned. Trying just id No vmkernel driver found for 'bus' '' at Spawned. No driver found for '8086:2570' '1458:2570' at 000:00.0. Trying just id No vmkernel driver found for '8086:2570' '1458:2570' at 000:00.0. No driver found for '8086:2572' '1458:2572' at 000:02.0. Trying just id No vmkernel driver found for '8086:2572' '1458:2572' at 000:02.0. No driver found for '8086:24d2' '1458:24d2' at 000:29.0. Trying just id No vmkernel driver found for '8086:24d2' '1458:24d2' at 000:29.0. No driver found for '8086:24d4' '1458:24d2' at 000:29.1. Trying just id No vmkernel driver found for '8086:24d4' '1458:24d2' at 000:29.1. No driver found for '8086:24d7' '1458:24d2' at 000:29.2. Trying just id No vmkernel driver found for '8086:24d7' '1458:24d2' at 000:29.2. No driver found for '8086:24de' '1458:24d2' at 000:29.3. Trying just id No vmkernel driver found for '8086:24de' '1458:24d2' at 000:29.3. No driver found for '8086:24dd' '1458:5006' at 000:29.7. Trying just id No vmkernel driver found for '8086:24dd' '1458:5006' at 000:29.7. No driver found for '8086:244e' '0000:0000' at 000:30.0. Trying just id No vmkernel driver found for '8086:244e' '0000:0000' at 000:30.0. No driver found for '8086:24d0' '0000:0000' at 000:31.0. Trying just id No vmkernel driver found for '8086:24d0' '0000:0000' at 000:31.0. No driver found for '8086:24d1' '1458:24d1' at 000:31.2. Trying just id No driver found for '8086:24d3' '1458:24d2' at 000:31.3. Trying just id No vmkernel driver found for '8086:24d3' '1458:24d2' at 000:31.3. No driver found for '8086:24d5' '1458:a600' at 000:31.5. Trying just id No vmkernel driver found for '8086:24d5' '1458:a600' at 000:31.5. No driver found for '8086:1051' '1458:e000' at 001:08.0. Trying just id Loading VMkernel ata_piix.o (options: '') Using lib/vmware/ata_piix.o Module load of ata_piix succeeded. Loading VMkernel e100.o (options: '') Using lib/vmware/e100.o Module load of e100 succeeded. All drivers successfully loaded. Loading lvmdriver Using /lib/vmware/lvmdriver Module load of lvmdriver succeeded. Loading vmfs3 Using /lib/vmware/vmfs3 Module load of vmfs3 succeeded. (forcing normal run) Red Hat nash version 3.5.13.6 starting Creating block devices /lib/usb-ohci.o: init_module: Hint: insmod errors can be caused by incorrect module parameters, including invalid IO or IRQ parameters. You may find more information in syslog or the output from dmesg |
|
Hi Dave,
hp dc 7800:
bye, Reinhard ps: you have the Promise 300 TX4 two times in your SATA section on http://www.vm-help.com/esx/esx3.5/Whiteboxes_SATA_Controllers_for_ESX_3.5_3i.htm. ps: Award points if you find answers helpful. Thanks. |